Mode | Voltage | Style | Mounting | Design | Connection diameter | Air duct | Width | Height | Casing material | EC motor | Outdoor mounting | Sound-insulated casing | Heating | Current | Power | Maximum air flow | Sound pressure level | Frequency | RPM | Speed | Heat recovery efficiency | Maximum air capacity | Type | Weight | Power | Max. operating temperature | SEC class | Ingress protection rating | Phase | Sound pressure level at 3 m | Heat exchanger type | Heat exchanger material | Electric heater power | Transported air temperature | Current | Connected air duct diameter | Transported air temperature | Number of water coil rows | Humidity recovery efficiency | Insulation | Heat recovery efficiency | Total unit power | Sound pressure level at a distance of 1 m | Voltage | Max. unit power without an electric heater | Reheater power consumption | Maximum air flow | SFP | Weight | ErP | Maximum air flow | Extract filter | Supply filter | Motor IP rating | Max. power without electric heater | Max. unit power | Max. unit current without electric heater | Max. unit current | Max. unit power with electric heater | Max. unit current with electric heater | Current | Preheater power consumption | Filter | Electric heater current | Remote control panel | Functions | Power | Cable cross section | * | Max. water temperature | Water coil connection diameter |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
S-Vent 280х127-1.5-6D | 400 | - | floor mounting | centrifugal | - | for rectangular air ducts, for round air ducts | - | - | polymer-coated steel | no | yes | no | - | 4.2 | - | 3450 | - | 50 | 940 | - | - | - | Exhaust, Supply | 35.1 | 1500 | +60 | - | IP54 | 3 | 69 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 958 | - | - | - | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Extero 100 50 Hz |
230 | - | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | 0.31 | - | 325 | - | 50 | 2530 | - | - | - | Exhaust | - | 71 | +55 | C | IPX4 | 1 | 54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 90 | - | 4.1 | 2018 | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Extero 100 60 Hz |
230 | - | Inline | centrifugal | 100 | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | 0.40 | - | 350 | - | 60 | 2625 | - | - | - | Exhaust | - | 92 | +55 | C | IPX4 | 1 | 54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 97 | - | 4.1 | 2018 | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Blaubox EC MW 2000 S31 | 230 | - | ceiling mounting, wall mounting, floor mounting | centrifugal | - | for rectangular air ducts | - | - | aluzinc | yes | no | - | - | - | - | 2150 | - | 50 | - | - | - | - | Supply | - | - | - | - | - | 1 | 53 | - | - | - | -30…+40 | - | 500 x 300 | - | 4 | - | 30 mm mineral wool | - | - | - | - | - | - | - | - | 45 | 2018 | - | - | - | - | - | 387 | - | 1.7 | - | - | - | - | Coarce 90% / G4 (option: ePM1 70% / F7) | - | - | - | - | - | - | 150 | 1 |
KOMFORT EC LBE 700-E S21 | 230 | - | ceiling mounting, floor mounting | - | - | - | - | - | galvanized steel | - | - | - | - | - | - | 830 | - | 50/60 | - | - | - | - | - | - | - | - | A | - | 1 | 31 | counter-flow | enthalpy | 3600 | - | - | 250 | -25…+40 | - | - | 40 mm mineral wool | 74–89 | - | - | - | - | - | 231 | - | 108.4 | - | - | G4 | G4, F7 | - | 336 | - | 2.4 | - | 3936 | 18.0 | - | - | - | 15.6 | - | - | - | - | - | - | - |
Iso-ZS 315/2x250 6E | 230 | - | - | centrifugal | - | for round air ducts | - | - | galvanized steel | no | no | yes | - | 2.13 | - | - | - | 50 | 955 | - | - | 2610 | Exhaust, Supply | 31.0 | 427 | -20…+50 | - | IPX4 | 1 | 42 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | – | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
CIVIC EC LBE 300-E S21 | 230 | - | floor mounting | - | - | - | - | - | polymer-coated steel | yes | - | - | electric preheating | - | - | 320 | - | 50/60 | 2150 | - | - | - | Supply and exhaust | 137±3% | - | - | A | - | 1 | 21 | counter-flow | enthalpy | - | -25...+40 | - | 200 | - | - | - | 40 mm mineral wool | 73...89* | - | 31 | - | 125 | - | 89 | - | - | - | - | G4 x 2 | G4 + F8 (option: F8 C + H11) | - | - | - | 0.9 | - | - | 7 | - | 1400 | - | - | Sensor, LCD | Filter replacement indication, Timer, Weekly schedule, External sensor connection | - | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - |
Axis-QR 350 4D 50 Hz |
400 | - | wall mounting | axial | 350 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | 2350 | - | 50 | 1419 | - | - | - | Exhaust, Supply | - | 140 | - | - | IPX4 | 3 | 46 | - | - | - | - | - | - | -30...+60 | - | - | - | - | - | - | - | - | - | 653 | - | 7.5 | - | - | - | - | IP54 | - | - | - | - | - | - | 0.38 | - | - | - | - | - | - | - | - | - | - |
Axis-QR 350 4D 60 Hz |
400 | - | wall mounting | axial | 350 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | 2660 | - | 60 | 1638 | - | - | - | Exhaust, Supply | - | 150 | - | - | IPX4 | 3 | 46 | - | - | - | - | - | - | -30...+50 | - | - | - | - | - | - | - | - | - | 739 | - | 7.5 | - | - | - | - | IP54 | - | - | - | - | - | - | 0.46 | - | - | - | - | - | - | - | - | - | - |
Quatro Hi-Tech 150 | 220-240 | Hi-Tech | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | 0.13 | 24 | 265 | 37* | 50 | 2400 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 74 | 0.33 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - |
Box-FI 50x25 4E | 230 | - | Inline | centrifugal | - | for rectangular air ducts | 500 | 250 | galvanized steel | no | no | yes | - | 2.49 | - | 1750 | - | 50 | 1250 | - | - | - | Exhaust, Supply | - | 535 | - | - | IPX4 | 1 | 44 | - | - | - | - | - | - | -20...+40 | - | - | - | - | - | - | - | - | - | 486 | - | 40.5 | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tower-AL 200 (60 Hz) | 230 | - | for roof | axial | - | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | 0.21 | - | 470 | - | 60 | 1615 | - | - | - | Exhaust | 6.1 | 33 | 40 | - | IP24 | 1 | 31 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 131 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tower-AL 200 (50 Hz) | 230 | - | for roof | axial | - | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | 0.28 | - | 405 | - | 50 | 1300 | - | - | - | Exhaust | 6.1 | 43 | 40 | - | IP24 | 1 | 32 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 113 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Centro-MZ 315 L 50 Hz |
220-240 | - | ceiling mounting, wall mounting | centrifugal | 315 | for round air ducts | - | - | galvanized steel | no | no | no | - | 0.66 | - | 1330 | - | 50 | 2680 | - | - | - | Supply and exhaust | 6.57 | 151 | - | - | IPX4 | 1 | 52 | - | - | - | - | - | - | -25...+50 | - | - | - | - | - | - | - | - | - | 369 | - | - | 2018 | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Centro-MZ 315 L 60 Hz |
220-240 | - | ceiling mounting, wall mounting | centrifugal | 315 | for round air ducts | - | - | galvanized steel | no | no | no | - | 0.89 | - | 1370 | - | 60 | 2750 | - | - | - | Supply and exhaust | 6.57 | 205 | - | - | IPX4 | 1 | 52 | - | - | - | - | - | - | -25...+50 | - | - | - | - | - | - | - | - | - | 381 | - | - | 2018 | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
CIVIC EC DB 500 S21 V.2 | 230 | - | ceiling mounting | - | - | - | - | - | polymer-coated steel | yes | - | - | without heating | - | - | 510 | - | 50/60 | - | - | - | - | Supply and exhaust | 95 | - | - | A+ | - | 1 | 34 | counter-flow | polystyrene | - | -25...+40 | - | 250 | - | - | - | - | 83…96* | - | 44 | - | 238 | - | 142 | - | - | - | - | - | - | - | - | - | 1.7 | - | - | - | - | - | - | - | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | - | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - |
KOMFORT Ultra L 250-E S1 | 230 | - | ceiling mounting, wall mounting, floor mounting | - | - | for round air ducts | - | - | - | no | no | yes | - | - | - | 250 | - | 50/60 | - | - | - | - | Supply and exhaust | - | 148 | - | E | - | 1 | 28...47 | cross-flow | enthalpy | - | - | 0.78 | 125 | -25...+40 | - | 27...45 | 20 mm mineral wool | 52...73 | - | - | - | - | - | 69 | - | - | 2018 | - | G4 | G4 (option: F8 PM2.5 > 81 %) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-F 100x50 8D | 400 | - | Inline | centrifugal | - | for rectangular air ducts | 1000 | 500 | galvanized steel | no | no | no | - | 4.1 | - | 7175 | - | 50 | 680 | - | - | - | Exhaust, Supply | - | 2000 | -20...+40 | - | IPX4 | 3 | 59 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 1993 | - | 95.0 | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Valeo-E 75/100 (1 speed) |
- | - | ceiling mounting, wall mounting | centrifugal | - | for round air ducts | - | - | plastic | no | no | - | - | 0.11 | - | 75 | 29* | 50 | - | I | - | - | Exhaust | - | 24 | +50 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | 21 | - | - | - | - | - | - | IP55 | - | - | - | - | - | - | - | - | - | - | - | - | - | 3x1.5 | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - |
Valeo-E 75/100 (2 speed) |
- | - | ceiling mounting, wall mounting | centrifugal | - | for round air ducts | - | - | plastic | no | no | - | - | 0.13 | - | 100 | 38* | 50 | - | II | - | - | Exhaust | - | 29 | +50 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | 28 | - | - | - | - | - | - | IP55 | - | - | - | - | - | - | - | - | - | - | - | - | - | 3x1.5 | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - |
Box-I EC 100x50-3 max | 400 | - | Inline | centrifugal | - | for rectangular air ducts | - | - | galvanized steel | yes | no | yes | - | 5.00 | - | - | - | 50/60 | 1800 | - | - | 11190 | Exhaust, Supply | 130.0 | 3429 | -25...+50 | – | IPX4 | 3 | 47 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 2018 | 3109 | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tower-HC EC 190 | 230 | - | for roof | centrifugal | - | for round air ducts, for square air ducts | - | - | polymer-coated steel | yes | yes | no | - | 0.87 | - | 770 | - | 50/60 | 3538 | - | - | - | Exhaust | - | 110 | -25...+60 | – | IPX4 | 1 | 52 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 214 | - | 6 | 2018 | - | - | - | IP55 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
KOMFORT EC DB 250 S21 | 230 | - | ceiling mounting, wall mounting | - | - | for round air ducts | - | - | galvanized steel | yes | no | yes | - | - | - | 270 | - | 50/60 | - | - | 80...98 | - | Supply and exhaust | - | - | - | A | - | 1 | 28 | counter-flow | polystyrene | - | - | 0.8 | 125 | -25...+40 | - | - | 40 mm mineral wool | - | 101 | - | - | - | - | 75 | - | 48 | 2018 | - | G4 | F7 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tubo-M 250 [50 Hz] | 220-240 | - | Inline | axial | 250 | for round air ducts | - | - | polymer-coated steel | - | no | no | - | 0.48 | - | 1070 | - | 50 | 1300 | - | - | - | Supply and exhaust | 3.97 | 68 | -30 … +40 | – | IPX4 | 1 | 37 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 297 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tubo-M 250 [60 Hz] | 220-240 | - | Inline | axial | 250 | for round air ducts | - | - | polymer-coated steel | - | no | no | - | 0.51 | - | 1050 | - | 60 | 1450 | - | - | - | Supply and exhaust | 3.97 | 76 | -30 … +40 | – | IPX4 | 1 | 37 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 292 | - | - | - | - | - | - | IP44 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Aero 150 (127-220V/60Hz) | 127 | White | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | 0.175 | 25 | 270 | 39* | 60 | 2350 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 75 | 0.33 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - |
Aero 150 (127-220V/60Hz) | 220 | White | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | 0.338 | 25 | 270 | 39* | 60 | 2350 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 75 | 0.33 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - |
Iso-RB 400 (50 Hz) |
230 | - | Inline | centrifugal | 400 | for round air ducts | - | - | aluzinc | no | no | yes | - | 1.87 | - | 3800 | - | 50 | 1451 | - | - | - | Exhaust, Supply | - | 427 | - | - | IPX4 | 1 | 49 | - | - | - | - | - | - | -25...+55 | - | - | - | - | - | - | - | - | - | 1056 | - | 78.5 | 2018 | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-RB 400 (60 Hz) |
230 | - | Inline | centrifugal | 400 | for round air ducts | - | - | aluzinc | no | no | yes | - | 2.91 | - | 4100 | - | 60 | 1711 | - | - | - | Exhaust, Supply | - | 663 | - | - | IPX4 | 1 | 50 | - | - | - | - | - | - | -25...+55 | - | - | - | - | - | - | - | - | - | 1139 | - | 78.5 | 2018 | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tower-H 710 6D | 400 | - | for roof | centrifugal | - | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | 4.87 | - | 17010 | - | 50 | 945 | - | - | - | Exhaust | 134 | 2583 | -25…+70 | - | IPX4 | 3 | 67 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 4725 | - | - | 2018 | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Lux 150 | 220-240 | Chrome | wall mounting | axial | 150 | - | - | - | - | - | - | - | - | 0.13 | 24 | 258 | 37 | 50 | 2400 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 72 | 0.33 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Trio 100 | - | White | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | 0.05 | - | 90 | 29* | 50 | - | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | 25 | 0.32 | 0.45 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 8 | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - | - |
S-Vent 240x114-2.2-4D | 400 | - | floor mounting | centrifugal | - | for rectangular air ducts, for round air ducts | - | - | polymer-coated steel | no | yes | no | - | 5.1 | - | 2930 | - | 50 | 1420 | - | - | - | Exhaust, Supply | 30.5 | 2200 | +60 | - | IP54 | 3 | 74 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 814 | - | - | - | - | - | - | IP54 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |