Selected 1357 products
Mode Connection diameterCasing materialMountingEC motorWeightErPMotor IP ratingIngress protection ratingTransported air temperatureSound pressure level at 3 mRPMMaximum air flowMaximum air flowPowerVoltageCurrentPhaseFrequencySEC classSpeedMax. power without electric heaterInsulation thiknessExtract filterSupply filterConnected air duct diameterHeat recovery efficiencyHeat exchanger typeHeat exchanger materialPreheater power consumptionReheater power consumptionReheater power consumptionMax. current consumption with heater(s)Sound pressure level at 3 m in accordance with ISO 3741:2004HeatingRemote control panelFunctionsTypeDesignAir ductOutdoor mountingSound-insulated casingCurrentAir flow in heat recovery modeAir flow in heat recovery modeAir flow in ventilation modeAir flow in ventilation modeOutdoor sound pressure attenuation in accordance with DIN EN 20140Sound pressure level at 1 m in accordance with ISO 3741:2004FilterHeat recovery efficiency in accordance with DIBt LÜ-A 20SFPClassification of air flow sensitivity to pressure difference variations in accordance with EN 13141-8Indoor/outdoor airtightness classification of the complete unit in accordance with EN 13141-8******Insulation
Iso-Mix EC 125 125 polymer-coated steel ceiling mounting, wall mounting, floor mounting yes 4.6 2018 - IPX4 -25...+55 43 3750 125 450 40 230 0.37 1 50 B - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Iso-Mix EC 150 150 polymer-coated steel ceiling mounting, wall mounting, floor mounting yes 6.1 2018 - IPX4 -25...+55 38 3390 167 600 55 230 0.48 1 50 B - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Iso-Mix EC 160 160 polymer-coated steel ceiling mounting, wall mounting, floor mounting yes 6.3 2018 - IPX4 -25...+55 38 3390 167 600 55 230 0.48 1 50 B - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Iso-Mix EC 200 200 polymer-coated steel ceiling mounting, wall mounting, floor mounting yes 8 2018 - IPX4 -25...+55 43 3390 289 1040 123 230 1.02 1 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Iso-Mix EC 250 250 polymer-coated steel ceiling mounting, wall mounting, floor mounting yes 15 2018 - IPX4 -25...+55 42 2870 357 1285 169 230 1.38 1 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Iso-Mix EC 315 315 polymer-coated steel ceiling mounting, wall mounting, floor mounting yes 25 2018 - IPX4 -25...+55 46 2826 547 1970 284 230 1.25 1 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Freshbox 200 ERV WiFi
Speed I
- polymer-coated steel - - 55 - - - -15...+40 - 2000 8 30 - 230 - 1 50/60 A I 10 30 G4 G4 + F7 (Option: H13) 100 85 counter-flow enthalpy - 1.0 12 without heating Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - - - - - - - -
Freshbox 200 ERV WiFi
Speed II
- polymer-coated steel - - 55 - - - -15...+40 - 2000 17 60 - 230 - 1 50/60 A II 15 30 G4 G4 + F7 (Option: H13) 100 81 counter-flow enthalpy - 1.0 22 without heating Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - - - - - - - -
Freshbox 200 ERV WiFi
Speed III
- polymer-coated steel - - 55 - - - -15...+40 - 2000 25 90 - 230 - 1 50/60 A III 25 30 G4 G4 + F7 (Option: H13) 100 75 counter-flow enthalpy - 1.0 30 without heating Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - - - - - - - -
Freshbox 200 ERV WiFi
Speed IV
- polymer-coated steel - - 55 - - - -15...+40 - 2000 33 120 - 230 - 1 50/60 A IV 44 30 G4 G4 + F7 (Option: H13) 100 68 counter-flow enthalpy - 1.0 36 without heating Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - - - - - - - -
Freshbox 200 ERV WiFi
Speed V
- polymer-coated steel - - 55 - - - -15...+40 - 2000 56 200 - 230 - 1 50/60 A V 134 30 G4 G4 + F7 (Option: H13) 100 66 counter-flow enthalpy - 1.0 45 without heating Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - - - - - - - -
Freshbox E-200 ERV WiFi
Speed I
- polymer-coated steel - - 55 - - - -15...+40 - 2000 8 30 - 230 - 1 50/60 A I 10 30 G4 G4 + F7 (Option: H13) 100 85 counter-flow enthalpy 650 - 4.0 12 electric preheating Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - - - - - - - -
Freshbox E-200 ERV WiFi
Speed II
- polymer-coated steel - - 55 - - - -15...+40 - 2000 17 60 - 230 - 1 50/60 A II 15 30 G4 G4 + F7 (Option: H13) 100 81 counter-flow enthalpy 650 - 4.0 22 electric preheating Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - - - - - - - -
Freshbox E-200 ERV WiFi
Speed III
- polymer-coated steel - - 55 - - - -15...+40 - 2000 25 90 - 230 - 1 50/60 A III 25 30 G4 G4 + F7 (Option: H13) 100 75 counter-flow enthalpy 650 - 4.0 30 electric preheating Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - - - - - - - -
Freshbox E-200 ERV WiFi
Speed IV
- polymer-coated steel - - 55 - - - -15...+40 - 2000 33 120 - 230 - 1 50/60 A IV 44 30 G4 G4 + F7 (Option: H13) 100 68 counter-flow enthalpy 650 - 4.0 36 electric preheating Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - - - - - - - -
Freshbox E-200 ERV WiFi
Speed V
- polymer-coated steel - - 55 - - - -15...+40 - 2000 56 200 - 230 - 1 50/60 A V 134 30 G4 G4 + F7 (Option: H13) 100 66 counter-flow enthalpy 650 - 4.0 45 electric preheating Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - - - - - - - -
Freshbox E1-200 ERV WiFi
Speed I
- polymer-coated steel - - 55 - - - -15...+40 - 2000 8 30 - 230 - 1 50/60 A I 10 30 G4 G4 + F7 (Option: H13) 100 85 counter-flow enthalpy - 700 4.2 12 electric reheating Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - - - - - - - -
Freshbox E1-200 ERV WiFi
Speed II
- polymer-coated steel - - 55 - - - -15...+40 - 2000 17 60 - 230 - 1 50/60 A II 15 30 G4 G4 + F7 (Option: H13) 100 81 counter-flow enthalpy - 700 4.2 22 electric reheating Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - - - - - - - -
Freshbox E1-200 ERV WiFi
Speed III
- polymer-coated steel - - 55 - - - -15...+40 - 2000 25 90 - 230 - 1 50/60 A III 25 30 G4 G4 + F7 (Option: H13) 100 75 counter-flow enthalpy - 700 4.2 30 electric reheating Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - - - - - - - -
Freshbox E1-200 ERV WiFi
Speed IV
- polymer-coated steel - - 55 - - - -15...+40 - 2000 33 120 - 230 - 1 50/60 A IV 44 30 G4 G4 + F7 (Option: H13) 100 68 counter-flow enthalpy - 700 4.2 36 electric reheating Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - - - - - - - -
Freshbox E1-200 ERV WiFi
Speed V
- polymer-coated steel - - 55 - - - -15...+40 - 2000 56 200 - 230 - 1 50/60 A V 134 30 G4 G4 + F7 (Option: H13) 100 66 counter-flow enthalpy - 700 4.2 45 electric reheating Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - - - - - - - -
Freshbox E2-200 ERV WiFi
Speed I
- polymer-coated steel - - 55 - - - -15...+40 - 2000 8 30 - 230 - 1 50/60 A I 10 30 G4 G4 + F7 (Option: H13) 100 85 counter-flow enthalpy 650 - 700 7.2 12 electric preheating, electric reheating Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - - - - - - - -
Freshbox E2-200 ERV WiFi
Speed II
- polymer-coated steel - - 55 - - - -15...+40 - 2000 17 60 - 230 - 1 50/60 A II 15 30 G4 G4 + F7 (Option: H13) 100 81 counter-flow enthalpy 650 - 700 7.2 22 electric preheating, electric reheating Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - - - - - - - -
Freshbox E2-200 ERV WiFi
Speed III
- polymer-coated steel - - 55 - - - -15...+40 - 2000 25 90 - 230 - 1 50/60 A III 25 30 G4 G4 + F7 (Option: H13) 100 75 counter-flow enthalpy 650 - 700 7.2 30 electric preheating, electric reheating Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - - - - - - - -
Freshbox E2-200 ERV WiFi
Speed IV
- polymer-coated steel - - 55 - - - -15...+40 - 2000 33 120 - 230 - 1 50/60 A IV 44 30 G4 G4 + F7 (Option: H13) 100 68 counter-flow enthalpy 650 - 700 7.2 36 electric preheating, electric reheating Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - - - - - - - -
Freshbox E2-200 ERV WiFi
Speed V
- polymer-coated steel - - 55 - - - -15...+40 - 2000 56 200 - 230 - 1 50/60 A V 134 30 G4 G4 + F7 (Option: H13) 100 66 counter-flow enthalpy 650 - 700 7.2 45 electric preheating, electric reheating Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - - - - - - - - -
Iso-B EC 100 100 galvanized steel Inline yes - 2018 IP55 IPX4 -25...+60 32 3200 77 278 92.7 230 - 1 50/60 C - - - - - - - - - - - - - - - - - Exhaust, Supply centrifugal for round air ducts no yes 0.75 - - - - - - - - - - - - - - -
Iso-B EC 125 125 galvanized steel Inline yes - 2018 IP55 IPX4 -25...+60 34 3200 99 357 92.6 230 - 1 50/60 C - - - - - - - - - - - - - - - - - Exhaust, Supply centrifugal for round air ducts no yes 0.75 - - - - - - - - - - - - - - -
Iso-B EC 150 150 galvanized steel Inline yes - 2018 IP55 IPX4 -25...+60 35 3200 118 425 94.8 230 - 1 50/60 B - - - - - - - - - - - - - - - - - Exhaust, Supply centrifugal for round air ducts no yes 0.77 - - - - - - - - - - - - - - -
Iso-B EC 160 160 galvanized steel Inline yes - 2018 IP55 IPX4 -25...+60 35 3200 118 425 94.8 230 - 1 50/60 B - - - - - - - - - - - - - - - - - Exhaust, Supply centrifugal for round air ducts no yes 0.77 - - - - - - - - - - - - - - -
Iso-B EC 200 200 galvanized steel Inline yes - 2018 IP55 IPX4 -25...+60 37 2580 194 700 101.6 230 - 1 50/60 B - - - - - - - - - - - - - - - - - Exhaust, Supply centrifugal for round air ducts no yes 0.83 - - - - - - - - - - - - - - -
Iso-B EC 250 250 galvanized steel Inline yes - 2018 IP55 IPX4 -25...+60 40 2510 318 1145 163.7 230 - 1 50/60 B - - - - - - - - - - - - - - - - - Exhaust, Supply centrifugal for round air ducts no yes 1.34 - - - - - - - - - - - - - - -
Iso-B EC 315 315 galvanized steel Inline yes - 2018 IP55 IPX4 -25...+60 42 2620 350 1260 164.3 230 - 1 50/60 - - - - - - - - - - - - - - - - - Exhaust, Supply centrifugal for round air ducts no yes 1.35 - - - - - - - - - - - - - - -
Vento Eco A50-4 S Pro (1 speed) - - wall mounting yes - - - IP24 20(-30**) … +40 - 915 - - 1.00 100-240 - - 50/60 - - - - - - - - - - - - - - 12 - Sensor Filter replacement indication, Timer - - 160 - - 0.017 2 8 4 15 41 21 G3 (Option: F8 PM2,5 > 99 %*) up to 92 0.48 S3*** D1 Maximum air flow 40 m³/h With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed -
Vento Eco A50-4 S Pro (2 speed) - - wall mounting yes - - - IP24 20(-30**) … +40 - 1555 - - 2.10 100-240 - - 50/60 - - - - - - - - - - - - - - 18 - Sensor Filter replacement indication, Timer - - 160 - - 0.025 4 15 8 30 41 27 G3 (Option: F8 PM2,5 > 99 %*) up to 92 0.50 S3*** D1 Maximum air flow 40 m³/h With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed -
Vento Eco A50-4 S Pro (3 speed) - - wall mounting yes - - - IP24 20(-30**) … +40 - 2330 - - 4.30 100-240 - - 50/60 - - - - - - - - - - - - - - 20 - Sensor Filter replacement indication, Timer - - 160 - - 0.041 7 25 14 50 41 29 G3 (Option: F8 PM2,5 > 99 %*) up to 92 0.62 S3*** D1 Maximum air flow 40 m³/h With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed -
Vento Eco A50-4 S11 Pro (1 speed) - - wall mounting yes - - - IP24 20(-30**) … +40 - 915 - - 1.00 100-240 - - 50/60 - - - - - - - - - - - - - - 12 - Sensor Filter replacement indication, Timer - - 160 - - 0.017 2 8 4 15 41 21 G3 (Option: F8 PM2,5 > 99 %*) up to 92 0.48 S3*** D1 Maximum air flow 40 m³/h With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed -
Vento Eco A50-4 S11 Pro (2 speed) - - wall mounting yes - - - IP24 20(-30**) … +40 - 1555 - - 2.10 100-240 - - 50/60 - - - - - - - - - - - - - - 18 - Sensor Filter replacement indication, Timer - - 160 - - 0.025 4 15 8 30 41 27 G3 (Option: F8 PM2,5 > 99 %*) up to 92 0.50 S3*** D1 Maximum air flow 40 m³/h With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed -
Vento Eco A50-4 S11 Pro (3 speed) - - wall mounting yes - - - IP24 20(-30**) … +40 - 2330 - - 4.30 100-240 - - 50/60 - - - - - - - - - - - - - - 20 - Sensor Filter replacement indication, Timer - - 160 - - 0.041 7 25 14 50 41 29 G3 (Option: F8 PM2,5 > 99 %*) up to 92 0.62 S3*** D1 Maximum air flow 40 m³/h With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed -
KOMFORT EC S160 S11 - polymer-coated steel wall mounting, floor mounting yes 42 2016, 2018 - - -25...+40 24 3770 50 180 51 220-240 0.4 - 50/60 A - - - G4 F7 (option: G4) 125 88...98 counter-flow polystyrene - - - - - - - - - - - - - - - - - - - - - - - - - - - - 20 mm mineral wool
KOMFORT EC S160-E S11 - polymer-coated steel wall mounting, floor mounting yes 42 2016, 2018 - - -25...+40 24 3770 50 180 51 220-240 0.4 - 50/60 A - - - G4 F7 (option: G4) 125 80...94 counter-flow enthalpy - - - - - - - - - - - - - - - - - - - - - - - - - - - - 20 mm mineral wool
KOMFORT EC SB160 S11 - polymer-coated steel wall mounting, floor mounting yes 44 2016, 2018 - - -25...+40 24 3770 50 180 51 220-240 0.4 - 50/60 A - - - G4 F7 (option: G4) 125 88....98 counter-flow polystyrene - - - - - - - - - - - - - - - - - - - - - - - - - - - - 20 mm mineral wool
KOMFORT EC SB160-E S11 - polymer-coated steel wall mounting, floor mounting yes 44 2016, 2018 - - -25...+40 24 3770 50 180 51 220-240 0.4 - 50/60 A - - - G4 F7 (option: G4) 125 80...94 counter-flow enthalpy - - - - - - - - - - - - - - - - - - - - - - - - - - - - 20 mm mineral wool
KOMFORT EC S200 S11 - polymer-coated steel wall mounting, floor mounting yes 45 2016, 2018 - - -25...+60 24 2050 72 260 130 230 1.0 1 50/60 A+ - - - - G3 125 83–98 counter-flow enthalpy - - - - - - - - - - - - - - - - - - - - - - - - - - - - 25 mm mineral wool
KOMFORT EC S200-E S11 - polymer-coated steel wall mounting, floor mounting yes 45 2016, 2018 - - -25...+60 24 2050 72 260 130 230 1.0 1 50/60 A - - - - G3 125 74–94 counter-flow enthalpy - - - - - - - - - - - - - - - - - - - - - - - - - - - - 25 mm mineral wool