Mode | Connection diameter | Casing material | Mounting | EC motor | Weight | ErP | Motor IP rating | Ingress protection rating | Transported air temperature | Sound pressure level at 3 m | RPM | Maximum air flow | Maximum air flow | Power | Voltage | Current | Phase | Frequency | SEC class | Speed | Max. power without electric heater | Insulation thikness | Extract filter | Supply filter | Connected air duct diameter | Heat recovery efficiency | Heat exchanger type | Heat exchanger material | Preheater power consumption | Reheater power consumption | Reheater power consumption | Max. current consumption with heater(s) | Sound pressure level at 3 m in accordance with ISO 3741:2004 | Heating | Remote control panel | Functions | Type | Design | Air duct | Outdoor mounting | Sound-insulated casing | Current | Air flow in heat recovery mode | Air flow in heat recovery mode | Air flow in ventilation mode | Air flow in ventilation mode | Outdoor sound pressure attenuation in accordance with DIN EN 20140 | Sound pressure level at 1 m in accordance with ISO 3741:2004 | Filter | Heat recovery efficiency in accordance with DIBt LÜ-A 20 | SFP | Classification of air flow sensitivity to pressure difference variations in accordance with EN 13141-8 | Indoor/outdoor airtightness classification of the complete unit in accordance with EN 13141-8 | * | ** | *** | Insulation |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Iso-Mix EC 125 | 125 | polymer-coated steel | ceiling mounting, wall mounting, floor mounting | yes | 4.6 | 2018 | - | IPX4 | -25...+55 | 43 | 3750 | 125 | 450 | 40 | 230 | 0.37 | 1 | 50 | B | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-Mix EC 150 | 150 | polymer-coated steel | ceiling mounting, wall mounting, floor mounting | yes | 6.1 | 2018 | - | IPX4 | -25...+55 | 38 | 3390 | 167 | 600 | 55 | 230 | 0.48 | 1 | 50 | B | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-Mix EC 160 | 160 | polymer-coated steel | ceiling mounting, wall mounting, floor mounting | yes | 6.3 | 2018 | - | IPX4 | -25...+55 | 38 | 3390 | 167 | 600 | 55 | 230 | 0.48 | 1 | 50 | B | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-Mix EC 200 | 200 | polymer-coated steel | ceiling mounting, wall mounting, floor mounting | yes | 8 | 2018 | - | IPX4 | -25...+55 | 43 | 3390 | 289 | 1040 | 123 | 230 | 1.02 | 1 | 50 | – | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-Mix EC 250 | 250 | polymer-coated steel | ceiling mounting, wall mounting, floor mounting | yes | 15 | 2018 | - | IPX4 | -25...+55 | 42 | 2870 | 357 | 1285 | 169 | 230 | 1.38 | 1 | 50 | – | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-Mix EC 315 | 315 | polymer-coated steel | ceiling mounting, wall mounting, floor mounting | yes | 25 | 2018 | - | IPX4 | -25...+55 | 46 | 2826 | 547 | 1970 | 284 | 230 | 1.25 | 1 | 50 | – | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Freshbox 200 ERV WiFi Speed I |
- | polymer-coated steel | - | - | 55 | - | - | - | -15...+40 | - | 2000 | 8 | 30 | - | 230 | - | 1 | 50/60 | A | I | 10 | 30 | G4 | G4 + F7 (Option: H13) | 100 | 85 | counter-flow | enthalpy | — | - | — | 1.0 | 12 | without heating | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Freshbox 200 ERV WiFi Speed II |
- | polymer-coated steel | - | - | 55 | - | - | - | -15...+40 | - | 2000 | 17 | 60 | - | 230 | - | 1 | 50/60 | A | II | 15 | 30 | G4 | G4 + F7 (Option: H13) | 100 | 81 | counter-flow | enthalpy | — | - | — | 1.0 | 22 | without heating | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Freshbox 200 ERV WiFi Speed III |
- | polymer-coated steel | - | - | 55 | - | - | - | -15...+40 | - | 2000 | 25 | 90 | - | 230 | - | 1 | 50/60 | A | III | 25 | 30 | G4 | G4 + F7 (Option: H13) | 100 | 75 | counter-flow | enthalpy | — | - | — | 1.0 | 30 | without heating | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Freshbox 200 ERV WiFi Speed IV |
- | polymer-coated steel | - | - | 55 | - | - | - | -15...+40 | - | 2000 | 33 | 120 | - | 230 | - | 1 | 50/60 | A | IV | 44 | 30 | G4 | G4 + F7 (Option: H13) | 100 | 68 | counter-flow | enthalpy | — | - | — | 1.0 | 36 | without heating | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Freshbox 200 ERV WiFi Speed V |
- | polymer-coated steel | - | - | 55 | - | - | - | -15...+40 | - | 2000 | 56 | 200 | - | 230 | - | 1 | 50/60 | A | V | 134 | 30 | G4 | G4 + F7 (Option: H13) | 100 | 66 | counter-flow | enthalpy | — | - | — | 1.0 | 45 | without heating | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Freshbox E-200 ERV WiFi Speed I |
- | polymer-coated steel | - | - | 55 | - | - | - | -15...+40 | - | 2000 | 8 | 30 | - | 230 | - | 1 | 50/60 | A | I | 10 | 30 | G4 | G4 + F7 (Option: H13) | 100 | 85 | counter-flow | enthalpy | 650 | - | — | 4.0 | 12 | electric preheating | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Freshbox E-200 ERV WiFi Speed II |
- | polymer-coated steel | - | - | 55 | - | - | - | -15...+40 | - | 2000 | 17 | 60 | - | 230 | - | 1 | 50/60 | A | II | 15 | 30 | G4 | G4 + F7 (Option: H13) | 100 | 81 | counter-flow | enthalpy | 650 | - | — | 4.0 | 22 | electric preheating | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Freshbox E-200 ERV WiFi Speed III |
- | polymer-coated steel | - | - | 55 | - | - | - | -15...+40 | - | 2000 | 25 | 90 | - | 230 | - | 1 | 50/60 | A | III | 25 | 30 | G4 | G4 + F7 (Option: H13) | 100 | 75 | counter-flow | enthalpy | 650 | - | — | 4.0 | 30 | electric preheating | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Freshbox E-200 ERV WiFi Speed IV |
- | polymer-coated steel | - | - | 55 | - | - | - | -15...+40 | - | 2000 | 33 | 120 | - | 230 | - | 1 | 50/60 | A | IV | 44 | 30 | G4 | G4 + F7 (Option: H13) | 100 | 68 | counter-flow | enthalpy | 650 | - | — | 4.0 | 36 | electric preheating | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Freshbox E-200 ERV WiFi Speed V |
- | polymer-coated steel | - | - | 55 | - | - | - | -15...+40 | - | 2000 | 56 | 200 | - | 230 | - | 1 | 50/60 | A | V | 134 | 30 | G4 | G4 + F7 (Option: H13) | 100 | 66 | counter-flow | enthalpy | 650 | - | — | 4.0 | 45 | electric preheating | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Freshbox E1-200 ERV WiFi Speed I |
- | polymer-coated steel | - | - | 55 | - | - | - | -15...+40 | - | 2000 | 8 | 30 | - | 230 | - | 1 | 50/60 | A | I | 10 | 30 | G4 | G4 + F7 (Option: H13) | 100 | 85 | counter-flow | enthalpy | — | - | 700 | 4.2 | 12 | electric reheating | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Freshbox E1-200 ERV WiFi Speed II |
- | polymer-coated steel | - | - | 55 | - | - | - | -15...+40 | - | 2000 | 17 | 60 | - | 230 | - | 1 | 50/60 | A | II | 15 | 30 | G4 | G4 + F7 (Option: H13) | 100 | 81 | counter-flow | enthalpy | — | - | 700 | 4.2 | 22 | electric reheating | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Freshbox E1-200 ERV WiFi Speed III |
- | polymer-coated steel | - | - | 55 | - | - | - | -15...+40 | - | 2000 | 25 | 90 | - | 230 | - | 1 | 50/60 | A | III | 25 | 30 | G4 | G4 + F7 (Option: H13) | 100 | 75 | counter-flow | enthalpy | — | - | 700 | 4.2 | 30 | electric reheating | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Freshbox E1-200 ERV WiFi Speed IV |
- | polymer-coated steel | - | - | 55 | - | - | - | -15...+40 | - | 2000 | 33 | 120 | - | 230 | - | 1 | 50/60 | A | IV | 44 | 30 | G4 | G4 + F7 (Option: H13) | 100 | 68 | counter-flow | enthalpy | — | - | 700 | 4.2 | 36 | electric reheating | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Freshbox E1-200 ERV WiFi Speed V |
- | polymer-coated steel | - | - | 55 | - | - | - | -15...+40 | - | 2000 | 56 | 200 | - | 230 | - | 1 | 50/60 | A | V | 134 | 30 | G4 | G4 + F7 (Option: H13) | 100 | 66 | counter-flow | enthalpy | — | - | 700 | 4.2 | 45 | electric reheating | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Freshbox E2-200 ERV WiFi Speed I |
- | polymer-coated steel | - | - | 55 | - | - | - | -15...+40 | - | 2000 | 8 | 30 | - | 230 | - | 1 | 50/60 | A | I | 10 | 30 | G4 | G4 + F7 (Option: H13) | 100 | 85 | counter-flow | enthalpy | 650 | - | 700 | 7.2 | 12 | electric preheating, electric reheating | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Freshbox E2-200 ERV WiFi Speed II |
- | polymer-coated steel | - | - | 55 | - | - | - | -15...+40 | - | 2000 | 17 | 60 | - | 230 | - | 1 | 50/60 | A | II | 15 | 30 | G4 | G4 + F7 (Option: H13) | 100 | 81 | counter-flow | enthalpy | 650 | - | 700 | 7.2 | 22 | electric preheating, electric reheating | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Freshbox E2-200 ERV WiFi Speed III |
- | polymer-coated steel | - | - | 55 | - | - | - | -15...+40 | - | 2000 | 25 | 90 | - | 230 | - | 1 | 50/60 | A | III | 25 | 30 | G4 | G4 + F7 (Option: H13) | 100 | 75 | counter-flow | enthalpy | 650 | - | 700 | 7.2 | 30 | electric preheating, electric reheating | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Freshbox E2-200 ERV WiFi Speed IV |
- | polymer-coated steel | - | - | 55 | - | - | - | -15...+40 | - | 2000 | 33 | 120 | - | 230 | - | 1 | 50/60 | A | IV | 44 | 30 | G4 | G4 + F7 (Option: H13) | 100 | 68 | counter-flow | enthalpy | 650 | - | 700 | 7.2 | 36 | electric preheating, electric reheating | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Freshbox E2-200 ERV WiFi Speed V |
- | polymer-coated steel | - | - | 55 | - | - | - | -15...+40 | - | 2000 | 56 | 200 | - | 230 | - | 1 | 50/60 | A | V | 134 | 30 | G4 | G4 + F7 (Option: H13) | 100 | 66 | counter-flow | enthalpy | 650 | - | 700 | 7.2 | 45 | electric preheating, electric reheating | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-B EC 100 | 100 | galvanized steel | Inline | yes | - | 2018 | IP55 | IPX4 | -25...+60 | 32 | 3200 | 77 | 278 | 92.7 | 230 | - | 1 | 50/60 | C | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | centrifugal | for round air ducts | no | yes | 0.75 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-B EC 125 | 125 | galvanized steel | Inline | yes | - | 2018 | IP55 | IPX4 | -25...+60 | 34 | 3200 | 99 | 357 | 92.6 | 230 | - | 1 | 50/60 | C | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | centrifugal | for round air ducts | no | yes | 0.75 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-B EC 150 | 150 | galvanized steel | Inline | yes | - | 2018 | IP55 | IPX4 | -25...+60 | 35 | 3200 | 118 | 425 | 94.8 | 230 | - | 1 | 50/60 | B | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | centrifugal | for round air ducts | no | yes | 0.77 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-B EC 160 | 160 | galvanized steel | Inline | yes | - | 2018 | IP55 | IPX4 | -25...+60 | 35 | 3200 | 118 | 425 | 94.8 | 230 | - | 1 | 50/60 | B | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | centrifugal | for round air ducts | no | yes | 0.77 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-B EC 200 | 200 | galvanized steel | Inline | yes | - | 2018 | IP55 | IPX4 | -25...+60 | 37 | 2580 | 194 | 700 | 101.6 | 230 | - | 1 | 50/60 | B | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | centrifugal | for round air ducts | no | yes | 0.83 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-B EC 250 | 250 | galvanized steel | Inline | yes | - | 2018 | IP55 | IPX4 | -25...+60 | 40 | 2510 | 318 | 1145 | 163.7 | 230 | - | 1 | 50/60 | B | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | centrifugal | for round air ducts | no | yes | 1.34 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso-B EC 315 | 315 | galvanized steel | Inline | yes | - | 2018 | IP55 | IPX4 | -25...+60 | 42 | 2620 | 350 | 1260 | 164.3 | 230 | - | 1 | 50/60 | – | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | centrifugal | for round air ducts | no | yes | 1.35 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Vento Eco A50-4 S Pro (1 speed) | - | - | wall mounting | yes | - | - | - | IP24 | 20(-30**) … +40 | - | 915 | - | - | 1.00 | 100-240 | - | - | 50/60 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 12 | - | Sensor | Filter replacement indication, Timer | - | - | 160 | - | - | 0.017 | 2 | 8 | 4 | 15 | 41 | 21 | G3 (Option: F8 PM2,5 > 99 %*) | up to 92 | 0.48 | S3*** | D1 | Maximum air flow 40 m³/h | With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied | At III speed | - |
Vento Eco A50-4 S Pro (2 speed) | - | - | wall mounting | yes | - | - | - | IP24 | 20(-30**) … +40 | - | 1555 | - | - | 2.10 | 100-240 | - | - | 50/60 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 18 | - | Sensor | Filter replacement indication, Timer | - | - | 160 | - | - | 0.025 | 4 | 15 | 8 | 30 | 41 | 27 | G3 (Option: F8 PM2,5 > 99 %*) | up to 92 | 0.50 | S3*** | D1 | Maximum air flow 40 m³/h | With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied | At III speed | - |
Vento Eco A50-4 S Pro (3 speed) | - | - | wall mounting | yes | - | - | - | IP24 | 20(-30**) … +40 | - | 2330 | - | - | 4.30 | 100-240 | - | - | 50/60 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 20 | - | Sensor | Filter replacement indication, Timer | - | - | 160 | - | - | 0.041 | 7 | 25 | 14 | 50 | 41 | 29 | G3 (Option: F8 PM2,5 > 99 %*) | up to 92 | 0.62 | S3*** | D1 | Maximum air flow 40 m³/h | With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied | At III speed | - |
Vento Eco A50-4 S11 Pro (1 speed) | - | - | wall mounting | yes | - | - | - | IP24 | 20(-30**) … +40 | - | 915 | - | - | 1.00 | 100-240 | - | - | 50/60 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 12 | - | Sensor | Filter replacement indication, Timer | - | - | 160 | - | - | 0.017 | 2 | 8 | 4 | 15 | 41 | 21 | G3 (Option: F8 PM2,5 > 99 %*) | up to 92 | 0.48 | S3*** | D1 | Maximum air flow 40 m³/h | With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied | At III speed | - |
Vento Eco A50-4 S11 Pro (2 speed) | - | - | wall mounting | yes | - | - | - | IP24 | 20(-30**) … +40 | - | 1555 | - | - | 2.10 | 100-240 | - | - | 50/60 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 18 | - | Sensor | Filter replacement indication, Timer | - | - | 160 | - | - | 0.025 | 4 | 15 | 8 | 30 | 41 | 27 | G3 (Option: F8 PM2,5 > 99 %*) | up to 92 | 0.50 | S3*** | D1 | Maximum air flow 40 m³/h | With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied | At III speed | - |
Vento Eco A50-4 S11 Pro (3 speed) | - | - | wall mounting | yes | - | - | - | IP24 | 20(-30**) … +40 | - | 2330 | - | - | 4.30 | 100-240 | - | - | 50/60 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 20 | - | Sensor | Filter replacement indication, Timer | - | - | 160 | - | - | 0.041 | 7 | 25 | 14 | 50 | 41 | 29 | G3 (Option: F8 PM2,5 > 99 %*) | up to 92 | 0.62 | S3*** | D1 | Maximum air flow 40 m³/h | With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied | At III speed | - |
KOMFORT EC S160 S11 | - | polymer-coated steel | wall mounting, floor mounting | yes | 42 | 2016, 2018 | - | - | -25...+40 | 24 | 3770 | 50 | 180 | 51 | 220-240 | 0.4 | - | 50/60 | A | - | - | - | G4 | F7 (option: G4) | 125 | 88...98 | counter-flow | polystyrene | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 20 mm mineral wool |
KOMFORT EC S160-E S11 | - | polymer-coated steel | wall mounting, floor mounting | yes | 42 | 2016, 2018 | - | - | -25...+40 | 24 | 3770 | 50 | 180 | 51 | 220-240 | 0.4 | - | 50/60 | A | - | - | - | G4 | F7 (option: G4) | 125 | 80...94 | counter-flow | enthalpy | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 20 mm mineral wool |
KOMFORT EC SB160 S11 | - | polymer-coated steel | wall mounting, floor mounting | yes | 44 | 2016, 2018 | - | - | -25...+40 | 24 | 3770 | 50 | 180 | 51 | 220-240 | 0.4 | - | 50/60 | A | - | - | - | G4 | F7 (option: G4) | 125 | 88....98 | counter-flow | polystyrene | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 20 mm mineral wool |
KOMFORT EC SB160-E S11 | - | polymer-coated steel | wall mounting, floor mounting | yes | 44 | 2016, 2018 | - | - | -25...+40 | 24 | 3770 | 50 | 180 | 51 | 220-240 | 0.4 | - | 50/60 | A | - | - | - | G4 | F7 (option: G4) | 125 | 80...94 | counter-flow | enthalpy | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 20 mm mineral wool |
KOMFORT EC S200 S11 | - | polymer-coated steel | wall mounting, floor mounting | yes | 45 | 2016, 2018 | - | - | -25...+60 | 24 | 2050 | 72 | 260 | 130 | 230 | 1.0 | 1 | 50/60 | A+ | - | - | - | - | G3 | 125 | 83–98 | counter-flow | enthalpy | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 25 mm mineral wool |
KOMFORT EC S200-E S11 | - | polymer-coated steel | wall mounting, floor mounting | yes | 45 | 2016, 2018 | - | - | -25...+60 | 24 | 2050 | 72 | 260 | 130 | 230 | 1.0 | 1 | 50/60 | A | - | - | - | - | G3 | 125 | 74–94 | counter-flow | enthalpy | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 25 mm mineral wool |