Selected 262 products
Mode PhaseVoltageRPMSound pressure level at 3 mCasing materialTransported air temperature CurrentFrequencyMountingDesignAir ductEC motorOutdoor mountingSound-insulated casingTypeNumber of water coil rowsConnected air duct size Total unit powerSupply filterMaximum air flowMaximum air flowInsulationWeightErPSEC classWeight Connected air duct diameterMax. unit power without an electric heaterPreheater power consumptionReheater power consumptionMax. unit current without electric heaterMax. unit current with electric heaterExtract filterHeat exchanger typeHeat exchanger materialHeat recovery efficiencyHeatingRemote control panelFunctions*Sound pressure level at a distance of 1 mCurrentTransported air temperatureMotor IP ratingConnection diameterIngress protection ratingPower
BLAUBOX DW 3200-4 Pro 3 400 2730 57 aluzinc -25...+40 2.4 50 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts no no yes Supply 4 600х350 1330 G4 (Option: F7) 3260 906 50 mm mineral wool 94 2016, 2018 - - - - - - - - - - - - - - - - - - - - - - -
BLAUBOX DW 4100-3 Pro 3 400 2840 75 aluzinc -25...+70 4.3 50 ceiling mounting, wall mounting, floor mounting centrifugal for rectangular air ducts no no yes Supply 3 700х400 2300 G4 (Option: F7) 4100 1139 50 mm mineral wool 110 2016, 2018 - - - - - - - - - - - - - - - - - - - - - - -
CIVIC EC LB 300 S21 V.2 1 230 - 37 polymer-coated steel -25...+40 - 50/60 floor mounting - - yes - - Supply and exhaust - - - - 320 89 40 mm mineral wool - - A 100 200 96 - - 0.75 - - counter-flow polystyrene 85...94* without heating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule Heat recovery efficiency is specified in compliance with EN 13141-8 47 - - - - - -
CIVIC EC LBE 300 S21 V.2 1 230 - 37 polymer-coated steel -25...+40 - 50/60 floor mounting - - yes - - Supply and exhaust - - - - 320 89 40 mm mineral wool - - A 101 200 96 1050 - 0.75 7 - counter-flow polystyrene 85...94* electric preheating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 47 - - - - - -
CIVIC EC LBE2 300 S21 V.2 1 230 - 37 polymer-coated steel -25...+40 - 50/60 floor mounting - - yes - - Supply and exhaust - - - - 320 89 40 mm mineral wool - - A 103 200 96 1050 700 0.75 11 - counter-flow polystyrene 85...94* electric preheating, electric reheating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 47 - - - - - -
CIVIC EC LB 300-E S21 V.2 1 230 - 37 polymer-coated steel -25...+40 - 50/60 floor mounting - - yes - - Supply and exhaust - - - - 320 89 40 mm mineral wool - - A 100 200 96 - - 0.75 - - counter-flow enthalpy 73...89* without heating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 47 - - - - - -
CIVIC EC LBE 300-E S21 V.2 1 230 - 37 polymer-coated steel -25...+40 - 50/60 floor mounting - - yes - - Supply and exhaust - - - - 320 89 40 mm mineral wool - - A 101 200 96 1050 - 0.75 7 - counter-flow enthalpy 73...89* electric preheating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 47 - - - - - -
CIVIC EC LBE2 300-E S21 V.2 - 230 - 37 polymer-coated steel -25...+40 - 50/60 floor mounting - - yes - - Supply and exhaust - - - - 320 89 40 mm mineral wool - - A 103 200 96 1050 700 0.75 11 - counter-flow enthalpy 73...89* electric preheating, electric reheating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 47 - - - - - -
CIVIC EC LB 500 S21 V.2 - 230 - 38 polymer-coated steel -25...+40 - 50/60 floor mounting - - yes - - Supply and exhaust - - - - 580 161 40 mm mineral wool - - A 139 250 370 - - 2.5 - - counter-flow polystyrene 75...94* without heating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 47 - - - - - -
CIVIC EC LBE 500 S21 V.2 1 230 - 38 polymer-coated steel -25...+40 - 50/60 floor mounting - - yes - - Supply and exhaust - - - - 580 161 40 mm mineral wool - - A 140 250 370 1050 - 2.5 9.1 - counter-flow polystyrene 75...94* electric preheating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 47 - - - - - -
CIVIC EC LBE2 500 S21 V.2 1 230 - 38 polymer-coated steel -25...+40 - 50/60 floor mounting - - yes - - Supply and exhaust - - - - 580 161 40 mm mineral wool - - A 142 250 370 1050 700 2.5 13.3 - counter-flow polystyrene 75...94* electric preheating, electric reheating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 47 - - - - - -
CIVIC EC LBE2 1200 S21 V.2 3 400 - 30 polymer-coated steel -25...+40 - 50/60 floor mounting - - yes - - Supply and exhaust - - - - 1240 344 40 mm mineral wool - - 363 400 345 3150 2110 2.3 18.7 - counter-flow polystyrene 84…96* electric preheating, electric reheating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 40 - - - - - -
CIVIC EC LBE 1200 S21 V.2 3 230 - 30 polymer-coated steel -25...+40 - 50/60 floor mounting - - yes - - Supply and exhaust - - - - 1240 344 40 mm mineral wool - - A 358 400 345 3150 - 2.3 12 - counter-flow polystyrene 84…96* electric preheating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 40 - - - - - -
CIVIC EC LB 1200 S21 V.2 1 230 - 30 polymer-coated steel -25...+40 - 50/60 floor mounting - - yes - - Supply and exhaust - - - - 1240 344 40 mm mineral wool - - 352 400 345 - - 2.3 - - counter-flow polystyrene 84…96* without heating - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8 40 - - - - - -
Axis-Q EC 200 1 230 2780 50 polymer-coated steel - - 50/60 wall mounting axial for round air ducts yes no no Supply and exhaust - - - - 975 271 - 2.04 - - - - - - - - - - - - - - - - - - 0.4 –25…+60 IP55 210 IPX5 55
Axis-Q EC 500 1 230 1600 70 polymer-coated steel - - 50/60 wall mounting axial for round air ducts yes no no Supply and exhaust - - - - 8500 2361 - 8.31 - - - - - - - - - - - - - - - - - - 3.1 –25…+60 IP55 520 IPX5 700
Axis-QR EC 350 1 230 1670 58 polymer-coated steel - - 50/60 wall mounting axial for round air ducts yes no no Supply and exhaust - - - - 3500 972 - 3.8 - - - - - - - - - - - - - - - - - - 1.4 –25…+60 IP55 374 IPX5 200
Axis-QR EC 300 max 1 230 2200 57 polymer-coated steel - - 50/60 wall mounting axial for round air ducts yes no no Supply and exhaust - - - - 2750 764 - 2.8 - - - - - - - - - - - - - - - - - - 1.5 –25…+60 IP55 317 IPX5 210
Axis-QR EC 300 1 230 2000 57 polymer-coated steel - - 50/60 wall mounting axial for round air ducts yes no no Supply and exhaust - - - - 2400 667 - 2.7 - - - - - - - - - - - - - - - - - - 1.2 –25…+60 IP55 317 IPX5 150
Axis-QR EC 250 max 1 230 2950 57 polymer-coated steel - - 50/60 wall mounting axial for round air ducts yes no no Supply and exhaust - - - - 1850 514 - 2 - - - - - - - - - - - - - - - - - - 0.85 –25…+60 IP55 260 IPX5 115
Axis-QR EC 250 1 230 2480 50 polymer-coated steel - - 50/60 wall mounting axial for round air ducts yes no no Supply and exhaust - - - - 1550 431 - 2 - - - - - - - - - - - - - - - - - - 0.61 –25…+60 IP55 260 IPX5 85
Axis-QR EC 200 max 1 230 2900 54 polymer-coated steel - - 50/60 wall mounting axial for round air ducts yes no no Supply and exhaust - - - - 1600 444 - 1.7 - - - - - - - - - - - - - - - - - - 0.85 –25…+60 IP55 210 IPX5 115
Axis-QR EC 200 1 230 2780 50 polymer-coated steel - - 50/60 wall mounting axial for round air ducts yes no no Supply and exhaust - - - - 975 271 - 1.6 - - - - - - - - - - - - - - - - - - 0.4 –25…+60 IP55 210 IPX5 55
Axis-Q EC 250 max 1 230 2950 57 polymer-coated steel - - 50/60 wall mounting axial for round air ducts yes no no Supply and exhaust - - - - 1850 514 - 2.56 - - - - - - - - - - - - - - - - - - 0.85 –25…+60 IP55 260 IPX5 115
Axis-Q EC 300 1 230 2000 57 polymer-coated steel - - 50/60 wall mounting axial for round air ducts yes no no Supply and exhaust - - - - 2400 667 - 3.4 - - - - - - - - - - - - - - - - - - 1.2 –25…+60 IP55 317 IPX5 150