BLAUBOX DW 3200-4 Pro |
3
|
400
|
2730
|
57
|
aluzinc
|
-25...+40
|
2.4
|
50
|
ceiling mounting, wall mounting, floor mounting
|
centrifugal
|
for rectangular air ducts
|
no
|
no
|
yes
|
Supply
|
4
|
600х350
|
1330
|
G4 (Option: F7)
|
3260
|
906
|
50 mm mineral wool
|
94
|
2016, 2018
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
BLAUBOX DW 4100-3 Pro |
3
|
400
|
2840
|
75
|
aluzinc
|
-25...+70
|
4.3
|
50
|
ceiling mounting, wall mounting, floor mounting
|
centrifugal
|
for rectangular air ducts
|
no
|
no
|
yes
|
Supply
|
3
|
700х400
|
2300
|
G4 (Option: F7)
|
4100
|
1139
|
50 mm mineral wool
|
110
|
2016, 2018
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CIVIC EC LB 300 S21 V.2 |
1
|
230
|
-
|
37
|
polymer-coated steel
|
-25...+40
|
-
|
50/60
|
floor mounting
|
-
|
-
|
yes
|
-
|
-
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
320
|
89
|
40 mm mineral wool
|
-
|
-
|
A
|
100
|
200
|
96
|
-
|
-
|
0.75
|
-
|
-
|
counter-flow
|
polystyrene
|
85...94*
|
without heating
|
-
|
Wi-Fi, Filter replacement indication, Timer, Weekly schedule
|
Heat recovery efficiency is specified in compliance with EN 13141-8
|
47
|
-
|
-
|
-
|
-
|
-
|
-
|
CIVIC EC LBE 300 S21 V.2 |
1
|
230
|
-
|
37
|
polymer-coated steel
|
-25...+40
|
-
|
50/60
|
floor mounting
|
-
|
-
|
yes
|
-
|
-
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
320
|
89
|
40 mm mineral wool
|
-
|
-
|
A
|
101
|
200
|
96
|
1050
|
-
|
0.75
|
7
|
-
|
counter-flow
|
polystyrene
|
85...94*
|
electric preheating
|
-
|
Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection
|
Heat recovery efficiency is specified in compliance with EN 13141-8
|
47
|
-
|
-
|
-
|
-
|
-
|
-
|
CIVIC EC LBE2 300 S21 V.2 |
1
|
230
|
-
|
37
|
polymer-coated steel
|
-25...+40
|
-
|
50/60
|
floor mounting
|
-
|
-
|
yes
|
-
|
-
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
320
|
89
|
40 mm mineral wool
|
-
|
-
|
A
|
103
|
200
|
96
|
1050
|
700
|
0.75
|
11
|
-
|
counter-flow
|
polystyrene
|
85...94*
|
electric preheating, electric reheating
|
-
|
Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection
|
Heat recovery efficiency is specified in compliance with EN 13141-8
|
47
|
-
|
-
|
-
|
-
|
-
|
-
|
CIVIC EC LB 300-E S21 V.2 |
1
|
230
|
-
|
37
|
polymer-coated steel
|
-25...+40
|
-
|
50/60
|
floor mounting
|
-
|
-
|
yes
|
-
|
-
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
320
|
89
|
40 mm mineral wool
|
-
|
-
|
A
|
100
|
200
|
96
|
-
|
-
|
0.75
|
-
|
-
|
counter-flow
|
enthalpy
|
73...89*
|
without heating
|
-
|
Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection
|
Heat recovery efficiency is specified in compliance with EN 13141-8
|
47
|
-
|
-
|
-
|
-
|
-
|
-
|
CIVIC EC LBE 300-E S21 V.2 |
1
|
230
|
-
|
37
|
polymer-coated steel
|
-25...+40
|
-
|
50/60
|
floor mounting
|
-
|
-
|
yes
|
-
|
-
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
320
|
89
|
40 mm mineral wool
|
-
|
-
|
A
|
101
|
200
|
96
|
1050
|
-
|
0.75
|
7
|
-
|
counter-flow
|
enthalpy
|
73...89*
|
electric preheating
|
-
|
Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection
|
Heat recovery efficiency is specified in compliance with EN 13141-8
|
47
|
-
|
-
|
-
|
-
|
-
|
-
|
CIVIC EC LBE2 300-E S21 V.2 |
-
|
230
|
-
|
37
|
polymer-coated steel
|
-25...+40
|
-
|
50/60
|
floor mounting
|
-
|
-
|
yes
|
-
|
-
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
320
|
89
|
40 mm mineral wool
|
-
|
-
|
A
|
103
|
200
|
96
|
1050
|
700
|
0.75
|
11
|
-
|
counter-flow
|
enthalpy
|
73...89*
|
electric preheating, electric reheating
|
-
|
Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection
|
Heat recovery efficiency is specified in compliance with EN 13141-8
|
47
|
-
|
-
|
-
|
-
|
-
|
-
|
CIVIC EC LB 500 S21 V.2 |
-
|
230
|
-
|
38
|
polymer-coated steel
|
-25...+40
|
-
|
50/60
|
floor mounting
|
-
|
-
|
yes
|
-
|
-
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
580
|
161
|
40 mm mineral wool
|
-
|
-
|
A
|
139
|
250
|
370
|
-
|
-
|
2.5
|
-
|
-
|
counter-flow
|
polystyrene
|
75...94*
|
without heating
|
-
|
Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection
|
Heat recovery efficiency is specified in compliance with EN 13141-8
|
47
|
-
|
-
|
-
|
-
|
-
|
-
|
CIVIC EC LBE 500 S21 V.2 |
1
|
230
|
-
|
38
|
polymer-coated steel
|
-25...+40
|
-
|
50/60
|
floor mounting
|
-
|
-
|
yes
|
-
|
-
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
580
|
161
|
40 mm mineral wool
|
-
|
-
|
A
|
140
|
250
|
370
|
1050
|
-
|
2.5
|
9.1
|
-
|
counter-flow
|
polystyrene
|
75...94*
|
electric preheating
|
-
|
Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection
|
Heat recovery efficiency is specified in compliance with EN 13141-8
|
47
|
-
|
-
|
-
|
-
|
-
|
-
|
CIVIC EC LBE2 500 S21 V.2 |
1
|
230
|
-
|
38
|
polymer-coated steel
|
-25...+40
|
-
|
50/60
|
floor mounting
|
-
|
-
|
yes
|
-
|
-
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
580
|
161
|
40 mm mineral wool
|
-
|
-
|
A
|
142
|
250
|
370
|
1050
|
700
|
2.5
|
13.3
|
-
|
counter-flow
|
polystyrene
|
75...94*
|
electric preheating, electric reheating
|
-
|
Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection
|
Heat recovery efficiency is specified in compliance with EN 13141-8
|
47
|
-
|
-
|
-
|
-
|
-
|
-
|
CIVIC EC LBE2 1200 S21 V.2 |
3
|
400
|
-
|
30
|
polymer-coated steel
|
-25...+40
|
-
|
50/60
|
floor mounting
|
-
|
-
|
yes
|
-
|
-
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
1240
|
344
|
40 mm mineral wool
|
-
|
-
|
–
|
363
|
400
|
345
|
3150
|
2110
|
2.3
|
18.7
|
-
|
counter-flow
|
polystyrene
|
84…96*
|
electric preheating, electric reheating
|
-
|
Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection
|
Heat recovery efficiency is specified in compliance with EN 13141-8
|
40
|
-
|
-
|
-
|
-
|
-
|
-
|
CIVIC EC LBE 1200 S21 V.2 |
3
|
230
|
-
|
30
|
polymer-coated steel
|
-25...+40
|
-
|
50/60
|
floor mounting
|
-
|
-
|
yes
|
-
|
-
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
1240
|
344
|
40 mm mineral wool
|
-
|
-
|
A
|
358
|
400
|
345
|
3150
|
-
|
2.3
|
12
|
-
|
counter-flow
|
polystyrene
|
84…96*
|
electric preheating
|
-
|
Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection
|
Heat recovery efficiency is specified in compliance with EN 13141-8
|
40
|
-
|
-
|
-
|
-
|
-
|
-
|
CIVIC EC LB 1200 S21 V.2 |
1
|
230
|
-
|
30
|
polymer-coated steel
|
-25...+40
|
-
|
50/60
|
floor mounting
|
-
|
-
|
yes
|
-
|
-
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
1240
|
344
|
40 mm mineral wool
|
-
|
-
|
–
|
352
|
400
|
345
|
-
|
-
|
2.3
|
-
|
-
|
counter-flow
|
polystyrene
|
84…96*
|
without heating
|
-
|
Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection
|
Heat recovery efficiency is specified in compliance with EN 13141-8
|
40
|
-
|
-
|
-
|
-
|
-
|
-
|
Axis-Q EC 200 |
1
|
230
|
2780
|
50
|
polymer-coated steel
|
-
|
-
|
50/60
|
wall mounting
|
axial
|
for round air ducts
|
yes
|
no
|
no
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
975
|
271
|
-
|
2.04
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
0.4
|
–25…+60
|
IP55
|
210
|
IPX5
|
55
|
Axis-Q EC 500 |
1
|
230
|
1600
|
70
|
polymer-coated steel
|
-
|
-
|
50/60
|
wall mounting
|
axial
|
for round air ducts
|
yes
|
no
|
no
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
8500
|
2361
|
-
|
8.31
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
3.1
|
–25…+60
|
IP55
|
520
|
IPX5
|
700
|
Axis-QR EC 350 |
1
|
230
|
1670
|
58
|
polymer-coated steel
|
-
|
-
|
50/60
|
wall mounting
|
axial
|
for round air ducts
|
yes
|
no
|
no
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
3500
|
972
|
-
|
3.8
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
1.4
|
–25…+60
|
IP55
|
374
|
IPX5
|
200
|
Axis-QR EC 300 max |
1
|
230
|
2200
|
57
|
polymer-coated steel
|
-
|
-
|
50/60
|
wall mounting
|
axial
|
for round air ducts
|
yes
|
no
|
no
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
2750
|
764
|
-
|
2.8
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
1.5
|
–25…+60
|
IP55
|
317
|
IPX5
|
210
|
Axis-QR EC 300 |
1
|
230
|
2000
|
57
|
polymer-coated steel
|
-
|
-
|
50/60
|
wall mounting
|
axial
|
for round air ducts
|
yes
|
no
|
no
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
2400
|
667
|
-
|
2.7
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
1.2
|
–25…+60
|
IP55
|
317
|
IPX5
|
150
|
Axis-QR EC 250 max |
1
|
230
|
2950
|
57
|
polymer-coated steel
|
-
|
-
|
50/60
|
wall mounting
|
axial
|
for round air ducts
|
yes
|
no
|
no
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
1850
|
514
|
-
|
2
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
0.85
|
–25…+60
|
IP55
|
260
|
IPX5
|
115
|
Axis-QR EC 250 |
1
|
230
|
2480
|
50
|
polymer-coated steel
|
-
|
-
|
50/60
|
wall mounting
|
axial
|
for round air ducts
|
yes
|
no
|
no
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
1550
|
431
|
-
|
2
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
0.61
|
–25…+60
|
IP55
|
260
|
IPX5
|
85
|
Axis-QR EC 200 max |
1
|
230
|
2900
|
54
|
polymer-coated steel
|
-
|
-
|
50/60
|
wall mounting
|
axial
|
for round air ducts
|
yes
|
no
|
no
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
1600
|
444
|
-
|
1.7
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
0.85
|
–25…+60
|
IP55
|
210
|
IPX5
|
115
|
Axis-QR EC 200 |
1
|
230
|
2780
|
50
|
polymer-coated steel
|
-
|
-
|
50/60
|
wall mounting
|
axial
|
for round air ducts
|
yes
|
no
|
no
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
975
|
271
|
-
|
1.6
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
0.4
|
–25…+60
|
IP55
|
210
|
IPX5
|
55
|
Axis-Q EC 250 max |
1
|
230
|
2950
|
57
|
polymer-coated steel
|
-
|
-
|
50/60
|
wall mounting
|
axial
|
for round air ducts
|
yes
|
no
|
no
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
1850
|
514
|
-
|
2.56
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
0.85
|
–25…+60
|
IP55
|
260
|
IPX5
|
115
|
Axis-Q EC 300 |
1
|
230
|
2000
|
57
|
polymer-coated steel
|
-
|
-
|
50/60
|
wall mounting
|
axial
|
for round air ducts
|
yes
|
no
|
no
|
Supply and exhaust
|
-
|
-
|
-
|
-
|
2400
|
667
|
-
|
3.4
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
1.2
|
–25…+60
|
IP55
|
317
|
IPX5
|
150
|