Mode | Speed | Voltage | Weight | Frequency | Phase | Sound-insulated casing | EC motor | Casing material | Air duct | Design | Outdoor mounting | Mounting | Type | ErP | Motor IP rating | Ingress protection rating | Max. operating temperature | Sound pressure level at 3 m | RPM | Maximum air flow | Maximum air flow | Current | Power | Spigot | Max. unit current | Max. unit power | Transported air temperature | Insulation | Connected air duct diameter | Heat recovery efficiency | Heat exchanger type | Heat exchanger material | Extract filter | Supply filter | Weight | SEC class | Transported air temperature | Max. unit power without an electric heater | Preheater power consumption | Reheater power consumption | Max. unit current without electric heater | Max. unit current with electric heater | Heating | Remote control panel | Functions | * | Sound pressure level at a distance of 1 m | Transported air temperature | Power |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Iso-Primo EC 355 | - | 230 | 20.7 | 50/60 | 1 | yes | yes | galvanized steel | for round air ducts | mixed-flow | no | Inline | Exhaust, Supply | 2018 | IP44 | IPX4 | - | 48 | 2470 | 3500 | 972 | 1.56 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -25...+55 | 353 |
Iso-Primo EC 400 | - | 230 | 22.8 | 50/60 | 1 | yes | yes | galvanized steel | for round air ducts | mixed-flow | no | Inline | Exhaust, Supply | 2018 | IP44 | IPX4 | - | - | 2580 | 5415 | 1504 | 4.80 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | -25...+55 | 726 |
inWave 100/125 50 Hz min speed |
min | 230 | 3.6 | 50 | 1 | yes | no | plastic | for round air ducts | mixed-flow | no | Inline | Exhaust, Supply | 2018 | IP44 | IPX4 | -25…+55 | 16 | 2252 | 173 | 48 | 0.81 | 9 | 125 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
inWave 100/125 50 Hz med speed |
med | 230 | 3.6 | 50 | 1 | yes | no | plastic | for round air ducts | mixed-flow | no | Inline | Exhaust, Supply | 2018 | IP44 | IPX4 | -25…+55 | 21 | 2662 | 240 | 67 | 0.09 | 13 | 125 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
inWave 100/125 50 Hz max speed |
max | 230 | 3.6 | 50 | 1 | yes | no | plastic | for round air ducts | mixed-flow | no | Inline | Exhaust, Supply | 2018 | IP44 | IPX4 | -25…+55 | 25 | 2810 | 320 | 89 | 0.10 | 21 | 125 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
inWave 100/125 60 Hz min speed |
min | 230 | 3.6 | 60 | 1 | yes | no | plastic | for round air ducts | mixed-flow | no | Inline | Exhaust, Supply | – | IP44 | IPX4 | -25…+55 | 16 | 1894 | 161 | 45 | 0.09 | 10 | 125 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
inWave 100/125 60 Hz med speed |
med | 230 | 3.6 | 60 | 1 | yes | no | plastic | for round air ducts | mixed-flow | no | Inline | Exhaust, Supply | – | IP44 | IPX4 | -25…+55 | 21 | 2402 | 204 | 57 | 0.10 | 13 | 125 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
inWave 100/125 60 Hz max speed |
max | 230 | 3.6 | 60 | 1 | yes | no | plastic | for round air ducts | mixed-flow | no | Inline | Exhaust, Supply | – | IP44 | IPX4 | -25…+55 | 25 | 3242 | 320 | 89 | 0.12 | 26 | 125 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
inWave 150/160 min |
min | 230 | 5.0 | 50 | 1 | yes | no | plastic | for round air ducts | mixed-flow | no | Inline | Exhaust, Supply, Supply and exhaust | 2018 | IP20 | IPX4 | –25…+55 | 20 | 1982 | 242 | 67 | 0.20 | 25 | 150/160 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
inWave 150/160 med |
med | 230 | 5.0 | 50 | 1 | yes | no | plastic | for round air ducts | mixed-flow | no | Inline | Exhaust, Supply, Supply and exhaust | 2018 | IP20 | IPX4 | –25…+55 | 26 | 2374 | 320 | 89 | 0.21 | 46 | 150/160 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
inWave 150/160 max |
max | 230 | 5.0 | 50 | 1 | yes | no | plastic | for round air ducts | mixed-flow | no | Inline | Exhaust, Supply, Supply and exhaust | 2018 | IP20 | IPX4 | –25…+55 | 33 | 2738 | 540 | 150 | 0.24 | 51 | 150/160 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
inWave EC 100/125 | - | 230 | 3.6 | 50/60 | 1 | yes | yes | plastic | for round air ducts | mixed-flow | no | Inline | Exhaust, Supply | 2018 | IP44 | IPX4 | -25…+55 | 28 | 3002 | 350 | 97 | 0.77 | 20 | 125 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
inWave EC 150/160 | - | 230 | 5.0 | 50/60 | 1 | - | yes | plastic | for round air ducts | mixed-flow | no | Inline | Exhaust, Supply | 2018 | IP44 | IPX4 | -25…+55 | 38 | 3506 | 600 | 167 | 0.49 | 55 | 150/160 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Reneo-Fit D 100 S14 | - | 230 | - | 50/60 | 1 | - | - | EPP | - | - | - | ceiling mounting | Supply and exhaust | - | - | - | - | 32 | - | 130 | 36 | - | - | - | 0.34 | 45 | -23…+40 | 25 mm | 100 / 125 | 82–94 | counter-flow | polystyrene | G4 / Coarse > 60 % | G4 / Coarse > 60 % (option: F7 / ePM1 60 %) | 8 | A+ | - | - | - | - | - | - | - | - | - | - | - | - | - |
Reneo-Fit D 100-E S14 | - | 230 | - | 50/60 | 1 | - | - | EPP | - | - | - | ceiling mounting | Supply and exhaust | - | - | - | - | 32 | - | 130 | 36 | - | - | - | 0.34 | 45 | -23…+40 | 25 mm | 100 / 125 | 73–88 | counter-flow | enthalpy | G4 / Coarse > 60 % | G4 / Coarse > 60 % (option: F7 / ePM1 60 %) | 8 | A | - | - | - | - | - | - | - | - | - | - | - | - | - |
CIVIC EC LB 300 S21 V.2 | - | 230 | 100 | 50/60 | 1 | - | yes | polymer-coated steel | - | - | - | floor mounting | Supply and exhaust | - | - | - | - | 37 | - | 320 | 89 | - | - | - | - | - | - | 40 mm mineral wool | 200 | 85...94* | counter-flow | polystyrene | - | - | - | A | -25...+40 | 96 | - | - | 0.75 | - | without heating | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | Heat recovery efficiency is specified in compliance with EN 13141-8 | 47 | - | - |
CIVIC EC LBE 300 S21 V.2 | - | 230 | 101 | 50/60 | 1 | - | yes | polymer-coated steel | - | - | - | floor mounting | Supply and exhaust | - | - | - | - | 37 | - | 320 | 89 | - | - | - | - | - | - | 40 mm mineral wool | 200 | 85...94* | counter-flow | polystyrene | - | - | - | A | -25...+40 | 96 | 1050 | - | 0.75 | 7 | electric preheating | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | Heat recovery efficiency is specified in compliance with EN 13141-8 | 47 | - | - |
CIVIC EC LBE2 300 S21 V.2 | - | 230 | 103 | 50/60 | 1 | - | yes | polymer-coated steel | - | - | - | floor mounting | Supply and exhaust | - | - | - | - | 37 | - | 320 | 89 | - | - | - | - | - | - | 40 mm mineral wool | 200 | 85...94* | counter-flow | polystyrene | - | - | - | A | -25...+40 | 96 | 1050 | 700 | 0.75 | 11 | electric preheating, electric reheating | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | Heat recovery efficiency is specified in compliance with EN 13141-8 | 47 | - | - |
CIVIC EC LB 300-E S21 V.2 | - | 230 | 100 | 50/60 | 1 | - | yes | polymer-coated steel | - | - | - | floor mounting | Supply and exhaust | - | - | - | - | 37 | - | 320 | 89 | - | - | - | - | - | - | 40 mm mineral wool | 200 | 73...89* | counter-flow | enthalpy | - | - | - | A | -25...+40 | 96 | - | - | 0.75 | - | without heating | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | Heat recovery efficiency is specified in compliance with EN 13141-8 | 47 | - | - |
CIVIC EC LBE 300-E S21 V.2 | - | 230 | 101 | 50/60 | 1 | - | yes | polymer-coated steel | - | - | - | floor mounting | Supply and exhaust | - | - | - | - | 37 | - | 320 | 89 | - | - | - | - | - | - | 40 mm mineral wool | 200 | 73...89* | counter-flow | enthalpy | - | - | - | A | -25...+40 | 96 | 1050 | - | 0.75 | 7 | electric preheating | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | Heat recovery efficiency is specified in compliance with EN 13141-8 | 47 | - | - |
CIVIC EC LBE2 300-E S21 V.2 | - | 230 | 103 | 50/60 | - | - | yes | polymer-coated steel | - | - | - | floor mounting | Supply and exhaust | - | - | - | - | 37 | - | 320 | 89 | - | - | - | - | - | - | 40 mm mineral wool | 200 | 73...89* | counter-flow | enthalpy | - | - | - | A | -25...+40 | 96 | 1050 | 700 | 0.75 | 11 | electric preheating, electric reheating | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | Heat recovery efficiency is specified in compliance with EN 13141-8 | 47 | - | - |
CIVIC EC LB 500 S21 V.2 | - | 230 | 139 | 50/60 | - | - | yes | polymer-coated steel | - | - | - | floor mounting | Supply and exhaust | - | - | - | - | 38 | - | 580 | 161 | - | - | - | - | - | - | 40 mm mineral wool | 250 | 75...94* | counter-flow | polystyrene | - | - | - | A | -25...+40 | 370 | - | - | 2.5 | - | without heating | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | Heat recovery efficiency is specified in compliance with EN 13141-8 | 47 | - | - |
CIVIC EC LBE 500 S21 V.2 | - | 230 | 140 | 50/60 | 1 | - | yes | polymer-coated steel | - | - | - | floor mounting | Supply and exhaust | - | - | - | - | 38 | - | 580 | 161 | - | - | - | - | - | - | 40 mm mineral wool | 250 | 75...94* | counter-flow | polystyrene | - | - | - | A | -25...+40 | 370 | 1050 | - | 2.5 | 9.1 | electric preheating | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | Heat recovery efficiency is specified in compliance with EN 13141-8 | 47 | - | - |
CIVIC EC LBE2 500 S21 V.2 | - | 230 | 142 | 50/60 | 1 | - | yes | polymer-coated steel | - | - | - | floor mounting | Supply and exhaust | - | - | - | - | 38 | - | 580 | 161 | - | - | - | - | - | - | 40 mm mineral wool | 250 | 75...94* | counter-flow | polystyrene | - | - | - | A | -25...+40 | 370 | 1050 | 700 | 2.5 | 13.3 | electric preheating, electric reheating | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | Heat recovery efficiency is specified in compliance with EN 13141-8 | 47 | - | - |
CIVIC EC LBE2 1200 S21 V.2 | - | 400 | 363 | 50/60 | 3 | - | yes | polymer-coated steel | - | - | - | floor mounting | Supply and exhaust | - | - | - | - | 30 | - | 1240 | 344 | - | - | - | - | - | - | 40 mm mineral wool | 400 | 84…96* | counter-flow | polystyrene | - | - | - | – | -25...+40 | 345 | 3150 | 2110 | 2.3 | 18.7 | electric preheating, electric reheating | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | Heat recovery efficiency is specified in compliance with EN 13141-8 | 40 | - | - |
CIVIC EC LBE 1200 S21 V.2 | - | 230 | 358 | 50/60 | 3 | - | yes | polymer-coated steel | - | - | - | floor mounting | Supply and exhaust | - | - | - | - | 30 | - | 1240 | 344 | - | - | - | - | - | - | 40 mm mineral wool | 400 | 84…96* | counter-flow | polystyrene | - | - | - | A | -25...+40 | 345 | 3150 | - | 2.3 | 12 | electric preheating | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | Heat recovery efficiency is specified in compliance with EN 13141-8 | 40 | - | - |
CIVIC EC LB 1200 S21 V.2 | - | 230 | 352 | 50/60 | 1 | - | yes | polymer-coated steel | - | - | - | floor mounting | Supply and exhaust | - | - | - | - | 30 | - | 1240 | 344 | - | - | - | - | - | - | 40 mm mineral wool | 400 | 84…96* | counter-flow | polystyrene | - | - | - | – | -25...+40 | 345 | - | - | 2.3 | - | without heating | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | Heat recovery efficiency is specified in compliance with EN 13141-8 | 40 | - | - |
CIVIC EC DB 300 S21 V.2 | - | 230 | 78 | 50/60 | 1 | - | yes | polymer-coated steel | - | - | - | ceiling mounting, wall mounting | Supply and exhaust | - | - | - | - | 34 | - | 300 | 83 | - | - | - | - | - | - | - | 200 | 83…92* | counter-flow | polystyrene | - | - | - | A+ | -25...+40 | 204 | - | - | 1.5 | - | without heating | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | Heat recovery efficiency is specified in compliance with EN 13141-8 | 44 | - | - |
CIVIC EC DBE 300 S21 V.2 | - | 230 | 79 | 50/60 | 1 | - | yes | polymer-coated steel | - | - | - | ceiling mounting | Supply and exhaust | - | - | - | - | 34 | - | 300 | 83 | - | - | - | - | - | - | - | 200 | 83…92* | counter-flow | polystyrene | - | - | - | A+ | -25...+40 | 204 | 1050 | - | 1.5 | 7.7 | electric preheating | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | Heat recovery efficiency is specified in compliance with EN 13141-8 | 44 | - | - |
CIVIC EC DBE2 300 S21 V.2 | - | 230 | 80 | 50/60 | 1 | - | yes | polymer-coated steel | - | - | - | ceiling mounting | Supply and exhaust | - | - | - | - | 34 | - | 300 | 83 | - | - | - | - | - | - | - | 200 | 83…92* | counter-flow | polystyrene | - | - | - | A+ | -25...+40 | 204 | 1050 | 700 | 1.5 | 11.7 | electric preheating, electric reheating | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | Heat recovery efficiency is specified in compliance with EN 13141-8 | 44 | - | - |
CIVIC EC DB 500 S21 V.2 | - | 230 | 95 | 50/60 | 1 | - | yes | polymer-coated steel | - | - | - | ceiling mounting | Supply and exhaust | - | - | - | - | 34 | - | 510 | 142 | - | - | - | - | - | - | - | 250 | 83…96* | counter-flow | polystyrene | - | - | - | A+ | -25...+40 | 238 | - | - | 1.7 | - | without heating | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | Heat recovery efficiency is specified in compliance with EN 13141-8 | 44 | - | - |
CIVIC EC DBE 500 S21 V.2 | - | 230 | 95 | 50/60 | 1 | - | yes | polymer-coated steel | - | - | - | ceiling mounting | Supply and exhaust | - | - | - | - | 34 | - | 510 | 142 | - | - | - | - | - | - | - | 250 | 83…96* | counter-flow | polystyrene | - | - | - | A+ | -25...+40 | 238 | 1050 | - | 1.7 | 9.3 | electric preheating | - | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection | Heat recovery efficiency is specified in compliance with EN 13141-8 | 44 | - | - |