Login
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Online consultation from experts
Signup

Privacy policy

Equipment selection

x x м
м 3
м/час
Categories
All subcategories
  • Single-room reversible units Vento
  • Single-room units Freshbox
  • Single-room ventilation units Civic
  • Single-room ventilation units Hybrid
  • Single-room reversible units Solo
  • Single-room ventilation units Freshpoint
Additionally
Show ×
Voltage
Functions
Remote control panel
Heating
Casing material
Mounting
Hide filters
Fault
%
  • Selection method:
  • Air capacity:
  • Pressure:
Operating point
  • Air capacity: --
  • Pressure: ---
Print version
Search results
Selected 180 products
Mode VoltageMountingAir ductCasing materialEC motorHeatingCurrentPowerMaximum air flowFrequencyRPMSpeedHeat recovery efficiencyTypeWeight PowerSEC classIngress protection ratingPhaseSound pressure level at 3 mHeat exchanger typeHeat exchanger materialFan powerElectric heater powerSound pressure level at 1 mSound pressure level at 3 mOutdoor sound pressure attenuationRegeneration efficiencyTransported air temperature Connected air duct diameterAir flow in ventilation modeAir flow in heat recovery modeFilterTransported air temperatureOutdoor sound pressure attenuation in accordance with DIN EN 20140Regeneration efficiency in accordance with DIBt LÜ-A 20Humidity recovery efficiencyInsulationHeat recovery efficiencySound pressure level at a distance of 1 mVoltageMax. unit power without an electric heaterReheater power consumptionInsulation thiknessMaximum air flowSFPWeightMaximum air flowBypassExtract filterSupply filterAir flow in ventilation modeAir flow in heat recovery modeMax. power without electric heaterMax. unit current without electric heaterOperating temperatureMax. unit current with electric heaterCurrentPreheater power consumptionMax. current consumption with heater(s)Sound pressure level at 1 m in accordance with ISO 3741:2004Sound pressure level at 3 m in accordance with ISO 3741:2004FilterHeat recovery efficiency in accordance with DIBt LÜ-A 20Power with hood heating element offPower with hood heating element onCurrent with hood heating element offCurrent with hood heating element onAir flow in heat recovery modeAir flow in heat recovery modeRemote control panelFunctionsRemote control panelIndoor/outdoor airtightness classification of the complete unit in accordance with EN 13141-8Classification of air flow sensitivity to pressure difference variations in accordance with EN 13141-8Power********Transported air temperatureSound pressure level LpA to environment at 1 m distanceSound pressure level LpA to environment at 3 m distanceExtract filterSupply filterIntegrated electric preheater power
Vento Ergo A85-1 S Pro V.3
(1 speed)
- - 150 - yes - 0.034 - 36 50/60 1000 I - - - 4.74 - IP24 1 - - - - - - - - - - - - 18 - -20...+40 40 - - - - - 100-240 - - - 10 0.95 - - - - - - 5 - - - - - - - 29 19 G3 (Option: G4, F8 PM2.5 > 99 %*) up to 90 - - - - - - - Filter replacement indication, Timer, Humidity sensor yes - - - Maximum air flow 40 m³/h - - - - - - - - -
Vento Ergo A85-1 S Pro V.3
(2 speed)
- - 150 - yes - 0.050 - 59 50/60 1500 II - - - 6.56 - IP24 1 - - - - - - - - - - - - 30 - -20...+40 40 - - - - - 100-240 - - - 16 0.80 - - - - - - 8 - - - - - - - 35 25 G3 (Option: G4, F8 PM2.5 > 99 %*) up to 90 - - - - - - - Filter replacement indication, Timer, Humidity sensor yes - - - Maximum air flow 40 m³/h - - - - - - - - -
Vento Ergo A85-1 S Pro V.3
(3 speed)
- - 150 - yes - 0.071 - 85 50/60 2045 III - - - 9.65 - IP24 1 - - - - - - - - - - - - 43 - -20...+40 40 - - - - - 100-240 - - - 24 0.82 - - - - - - 12 - - - - - - - 44 34 G3 (Option: G4, F8 PM2.5 > 99 %*) up to 90 - - - - - - - Filter replacement indication, Timer, Humidity sensor yes - - - Maximum air flow 40 m³/h - - - - - - - - -
Freshpoint 160-E Pro L055 230 wall mounting - - yes electric heating - up to 22 - 50/60 - - - - - - A IPX4 1 - - - - 100 - 42 - - - - - - - -30...+50 - - - - up to 88 - - - - - - - - 57 - - - - - - - - - - - - - - - - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, Carbon dioxide sensor, Air quality sensor, Light sensor - - - - - - - - - - - - - -
Freshbox E-100 black
Speed I
230 wall mounting - polymer-coated steel yes electric preheating - - 30 50/60 2200 I - - 31 - A - 1 - counter-flow polystyrene - - - - - - - 100 - - - -20...+40 - - - - 98 - - - - 10 8 - - - - G4 G4, F8 (Option: F8 C, H13) - - 12 0.4 - 3.6 - 700 - - 13 - - - - - - - - LCD Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
Freshbox E-100 black
Speed II
230 wall mounting - polymer-coated steel yes electric preheating - - 60 50/60 2200 II - - 31 - A - 1 - counter-flow polystyrene - - - - - - - 100 - - - -20...+40 - - - - 92 - - - - 10 17 - - - - G4 G4, F8 (Option: F8 C, H13) - - 21 0.4 - 3.6 - 700 - - 27 - - - - - - - - LCD Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
Freshbox E-100 black
Speed III
230 wall mounting - polymer-coated steel yes electric preheating - - 100 50/60 2200 III - - 31 - A - 1 - counter-flow polystyrene - - - - - - - 100 - - - -20...+40 - - - - 89 - - - - 10 28 - - - - G4 G4, F8 (Option: F8 C, H13) - - 45 0.4 - 3.6 - 700 - - 39 - - - - - - - - LCD Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
CIVIC EC DB 300 S21 V.2 230 ceiling mounting, wall mounting - polymer-coated steel yes without heating - - 300 50/60 - - - Supply and exhaust 78 - A+ - 1 34 counter-flow polystyrene - - - - - - -25...+40 200 - - - - - - - - 83…92* 44 - 204 - - 83 - - - - - - - - - 1.5 - - - - - - - - - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
VENTO A50 S Pro (1 speed) 220-240 wall mounting 150 - - - 0.021 - 26 50 599 - - - - 3.68 A IP24 - - - - - - 24 14 18 ≤ 90 - - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - - - - - - - - - -
VENTO A50 S Pro (2 speed) 220-240 wall mounting 150 - - - 0.026 - 53 50 1155 - - - - 4.83 A IP24 - - - - - - 34 24 18 ≤ 90 - - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - - - - - - - - - -
Vento Expert A50-1 S W V.3
(I speed)
100-240 - 160 - yes - 0.035 - - 50/60 800 I - - - - - IP24 - - - - - - - - - - - - 15 8 - -20...+40 41/47** - - - - - - - - - - 2.4 - - - - - 4 2 - - - - - - - 13 4 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 S3*** 5.0 Maximum air flow 40 m³/h with open and closed front panel manual setting of 100% speed in a mobile application - - - - - - -
Vento Expert A50-1 S W V.3
(II speed)
100-240 - 160 - yes - 0.04 - - 50/60 1300 II - - - - - IP24 - - - - - - - - - - - - 30 15 - -20...+40 41/47** - - - - - - - - - - 1.44 - - - - - 8 4 - - - - - - - 25 16 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 S3*** 6.0 Maximum air flow 40 m³/h with open and closed front panel manual setting of 100% speed in a mobile application - - - - - - -
Vento Expert A50-1 S W V.3
(III speed)
100-240 - 160 - yes - 0.059 - - 50/60 1900 III - - - - - IP24 - - - - - - - - - - - - 50 25 - -20...+40 41/47** - - - - - - - - - - 1.22 - - - - - 14 7 - - - - - - - 37 28 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 S3*** 8.5 Maximum air flow 40 m³/h with open and closed front panel manual setting of 100% speed in a mobile application - - - - - - -
CIVIC EC DB 500 S21 230 ceiling mounting - polymer-coated steel yes without heating - - 510 50/60 1700 - - Supply and exhaust 126 - A - 1 24 counter-flow polystyrene - - - - - - -25...+40 250 - - - - - - - 25 mm, cellular synthetic rubber 74...86* 34 - 170 - - 142 - - - - G4 G4, F8 (option F8 C + H11) - - - 1.7 - 1.7 - - - - - - - - - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
Freshbox 100 ERV
Speed I
110-240 wall mounting - polymer-coated steel yes without heating - - 30 50/60 2200 I - - 31 - A - 1 - counter-flow enthalpy membrane - - - - - - - 100 - - - -20...+40 - - - - 96 - - - - 10 8 - - - - G4 G4, F8 (Option: F8 C, H13) - - 12 0.4 - - - - - - 13 - - - - - - - - LCD Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
Freshbox 100 ERV
Speed II
110-240 wall mounting - polymer-coated steel yes without heating - - 60 50/60 2200 II - - 31 - A - 1 - counter-flow enthalpy membrane - - - - - - - 100 - - - -20...+40 - - - - 89 - - - - 10 17 - - - - G4 G4, F8 (Option: F8 C, H13) - - 21 0.4 - - - - - - 27 - - - - - - - - LCD Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
Freshbox 100 ERV
Speed III
110-240 wall mounting - polymer-coated steel yes without heating - - 100 50/60 2200 III - - 31 - A - 1 - counter-flow enthalpy membrane - - - - - - - 100 - - - -20...+40 - - - - 83 - - - - 10 28 - - - - G4 G4, F8 (Option: F8 C, H13) - - 45 0.4 - - - - - - 39 - - - - - - - - LCD Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
CIVIC EC LBE 500 S21 V.2 230 floor mounting - polymer-coated steel yes electric preheating - - 580 50/60 - - - Supply and exhaust 140 - A - 1 38 counter-flow polystyrene - - - - - - -25...+40 250 - - - - - - - 40 mm mineral wool 75...94* 47 - 370 - - 161 - - - - - - - - - 2.5 - 9.1 - 1050 - - - - - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
VENTO A50-1 (1 speed) 220-240 wall mounting 150 - - - 0.021 - 26 50 599 - - - - 3.68 A IP24 - - - - - - 24 14 18 ≤ 90 - - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - - - - - - - - - -
VENTO A50-1 (2 speed) 220-240 wall mounting 150 - - - 0.026 - 53 50 1155 - - - - 4.83 A IP24 - - - - - - 34 24 18 ≤ 90 - - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - - - - - - - - - -
CIVIC EC DBE 1000 S21 400 ceiling mounting - polymer-coated steel yes electric preheating - - 1000 50/60 2070 - - Supply and exhaust 271 - A+ - 3 24 counter-flow polystyrene - - - - - - -25...+40 315 - - - - - - - 25 mm, cellular synthetic rubber 83...93* 34 - 260 - - 278 - - - - G4 x 2 G4x2 + (option: F7 x 2) - - - 1.85 - 11.2 - 6300 - - - - - - - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
CIVIC EC LBE 500 S21 230 floor mounting - polymer-coated steel yes electric preheating - - 580 50/60 1280 - - Supply and exhaust 193±3% - A - 1 25 counter-flow polystyrene - - - - - - -25...+40 250 - - - - - - - 40 mm mineral wool 75...94* 35 - 230 - - 161 - - - - G4 x 2 G4 + F8 (option: F8 C + H11) - - - 1.7 - 7.8 - 1400 - - - - - - - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
Freshpoint Eco 160 - wall mounting - - yes without heating - 8 - - - - - - - - A - - - сeramic - - - - 40 - - - - - - - -30...+50 40 - - - up to 92 - - - - - - - - 48 - - - - - - - - - - - - - - - - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, Light sensor - D2 S2 - - - - - - - - - - -
VENTO V50-1 (1 speed) 220-240 wall mounting 164x164 - - - 0.021 - 26 50 599 - - - - 3.68 A IP24 - - - - - - 24 14 19 ≤ 90 - - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - - - - - - - - - -
VENTO V50-1 (2 speed) 220-240 wall mounting 164x164 - - - 0.026 - 53 50 1155 - - - - 4.83 A IP24 - - - - - - 34 24 19 ≤ 90 - - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - - - - - - - - - -
CIVIC EC LB 300 S14 230 floor mounting - polymer-coated steel yes without heating - - 320 50/60 2150 - - Supply and exhaust 138±3% - A - 1 21 counter-flow polystyrene - - - - - - -25...+40 200 - - - - - - - 40 mm mineral wool 78...92* 31 - 125 - - 89 - - - - G4 x 2 G4 + F8 (option: F8 C + H11) - - - 0.9 - 0.9 - - - - - - - - - - - - - Sensor Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
CIVIC EC LBE2 300 230 floor mounting - polymer-coated steel yes electric preheating, electric reheating - - 320 50/60 2150 - - Supply and exhaust 140±3% - A - 1 21 counter-flow polystyrene - - - - - - -25...+40 200 - - - - - - - 40 mm mineral wool 78...92* 31 - 125 1400 - 89 - - - - G4 x 2 G4 + F8 (option: F8 C + H11) - - - 0.9 - 13.1 - 1400 - - - - - - - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
Freshpoint 160-E Pro 230 wall mounting - - yes electric heating - up to 22 - 50/60 - - - - - - A IPX4 1 - - - - 100 - 42 - - - - - - - -30...+50 - - - - up to 88 - - - - - - - - 57 - - - - - - - - - - - - - - - - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, Carbon dioxide sensor, Air quality sensor, Light sensor - - - - - - - - - - - - - -
VENTO Solar V60 Pro (1 speed) - wall mounting - - - - 0.018 2.8 35 - 1150 - - - - - A+ IP24 - 24 - - - - - - 19 up to 88 - - - - - - - - - - - 34 12 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
VENTO Solar V60 Pro (2 speed) - wall mounting - - - - 0.028 4.8 58 - 2100 - - - - - A+ IP24 - 29 - - - - - - 19 up to 88 - - - - - - - - - - - 41 12 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
CIVIC EC LBE2 300 S21 V.2 230 floor mounting - polymer-coated steel yes electric preheating, electric reheating - - 320 50/60 - - - Supply and exhaust 103 - A - 1 37 counter-flow polystyrene - - - - - - -25...+40 200 - - - - - - - 40 mm mineral wool 85...94* 47 - 96 700 - 89 - - - - - - - - - 0.75 - 11 - 1050 - - - - - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
VENTO Expert A50-1 S W V.2 (1 speed) 100-240 wall mounting 160 - yes - 0.035 - - 50/60 800 - - - - 4.45 - IP24 - - - - - - - - - - - - 15 8 - - 42 - - - - - - - - - - 2.14 - - - - - 4 2 - - - - - - - 20 11 G3 (option: pollen filter) up to 93 - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 S2** - - - - - -20...+40 - - - - -
VENTO Expert A50-1 S W V.2 (2 speed) 100-240 wall mounting 160 - yes - 0.040 - - 50/60 1300 - - - - 5.08 - IP24 - - - - - - - - - - - - 30 15 - - 42 - - - - - - - - - - 1.22 - - - - - 8 4 - - - - - - - 27 18 G3 (option: pollen filter) up to 93 - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 S2** - - - - - -20...+40 - - - - -
VENTO Expert A50-1 S W V.2 (3 speed) 100-240 wall mounting 160 - yes - 0.059 - - 50/60 1900 - - - - 7.06 - IP24 - - - - - - - - - - - - 50 25 - - 42 - - - - - - - - - - 1.02 - - - - - 14 7 - - - - - - - 30 21 G3 (option: pollen filter) up to 93 - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 S2** - - - - - -20...+40 - - - - -
VENTO inHome mini W
(1st speed)
100-240 wall mounting 100 - yes - 0.02 - - 50/60 - I - - - 1.0 - IP24 - - - - - - 20 10 - - - - 8 4 - -15...+40 40 / 44 - - - up to 81% - - - - - - 0.90 - - - - - 2 1 - - - - - - - - - ISO Coarse >50% (G3) (ISO Coarse >60% (G4), ISO ePM1 60% (F7) optional) - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Humidity sensor, External sensor connection, Automatic shutters - - - - - - - - - - - - - -
VENTO inHome mini W
(2nd speed)
100-240 wall mounting 100 - yes - 0.03 - - 50/60 - II - - - 1.6 - IP24 - - - - - - 26 16 - - - - 16 8 - -15...+40 40 / 44 - - - up to 81% - - - - - - 0.72 - - - - - 4 2 - - - - - - - - - ISO Coarse >50% (G3) (ISO Coarse >60% (G4), ISO ePM1 60% (F7) optional) - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Humidity sensor, External sensor connection, Automatic shutters - - - - - - - - - - - - - -
VENTO inHome mini W
(3rd speed)
100-240 wall mounting 100 - yes - 0.04 - - 50/60 - III - - - 3.0 - IP24 - - - - - - 33 23 - - - - 25 13 - -15...+40 40 / 44 - - - up to 81% - - - - - - 0.86 - - - - - 7 3 - - - - - - - - - ISO Coarse >50% (G3) (ISO Coarse >60% (G4), ISO ePM1 60% (F7) optional) - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Humidity sensor, External sensor connection, Automatic shutters - - - - - - - - - - - - - -
VENTO Eco2 A50 S1 Pro (1 speed) - wall mounting 160 - - - 0.030 - - 50/60 1030 - - - - 2.07 A IP24 - - - - - - 22 13 - - - - 15 15 G3 (F8 PM2.5 > 99 %) -20…+50 41 ≤ 92 - - - - 100-230 - - - - - - - - - - 4 4 - - - - - - - - - - - - - - - - - Sensor Filter replacement indication, Timer - - - - - - - - - - - - - -
VENTO Eco2 A50 S1 Pro (2 speed) - wall mounting 160 - - - 0.049 - - 50/60 1760 - - - - 4.15 A IP24 - - - - - - 29 20 - - - - 30 30 G3 (F8 PM2.5 > 99 %) -20…+50 41 ≤ 92 - - - - 100-230 - - - - - - - - - - 8 8 - - - - - - - - - - - - - - - - - Sensor Filter replacement indication, Timer - - - - - - - - - - - - - -
VENTO Eco2 A50 S1 Pro (3 speed) - wall mounting 160 - - - 0.098 - - 50/60 2690 - - - - 10.10 A IP24 - - - - - - 32 23 - - - - 50 50 G3 (F8 PM2.5 > 99 %) -20…+50 41 ≤ 92 - - - - 100-230 - - - - - - - - - - 14 14 - - - - - - - - - - - - - - - - - Sensor Filter replacement indication, Timer - - - - - - - - - - - - - -
1 Speed 230 ceiling mounting, wall mounting - aluzinc - - - - 60 50/60 2800 - - Supply and exhaust - - A - 1 - counter-flow enthalpy membrane - - - - - - - 125 - - - - - - 47-60 - 74-89 - - 58 - - - - 47 - yes - - - - - 0.5 - 4 - - - - - - - - - - - - - - - - - - - - - - - - 25 16 - - 800
2 Speed 230 ceiling mounting, wall mounting - aluzinc - - - - 90 50/60 2800 - - Supply and exhaust - - A - 1 - counter-flow enthalpy membrane - - - - - - - 125 - - - - - - 47-60 - 74-89 - - 58 - - - - 47 - yes - - - - - 0.5 - 4 - - - - - - - - - - - - - - - - - - - - - - - - 35 26 - - 800
3 Speed 230 ceiling mounting, wall mounting - aluzinc - - - - 160 50/60 2800 - - Supply and exhaust - - A - 1 - counter-flow enthalpy membrane - - - - - - - 125 - - - - - - 47-60 - 74-89 - - 58 - - - - 47 - yes - - - - - 0.5 - 4 - - - - - - - - - - - - - - - - - - - - - - - - 42 32 - - 800
Solo A35 L S4 Pro R
(1 speed)
- - - - - - - - 30 - - I - - - 1.20 - IP24 - 27 сeramic - - - - - - - - - - - - -15...+40 - - - - ≤85 - 220-240 - - - 8 0.27 - - - - - - - - - - - 0.019 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Solo A35 L S4 Pro R
(2 speed)
- - - - - - - - 46 - - II - - - 1.70 - IP24 - 32 сeramic - - - - - - - - - - - - -15...+40 - - - - ≤85 - 220-240 - - - 13 0.27 - - - - - - - - - - - 0.025 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Vento Expert A100-1 S10 W V.2 BLK
(Speed I)
100-240 - 160 - yes - 0.037 - - 50/60 780 - - - - - - IP24 - - - - 3.20 - - - - - - - 18 9 - -20...+40 42 - - - - - - - - - - 1.28 - - - - - 5 3 - - - - - - - 23 13 G3 (Option: F7 PM2,5 > 99 %*) up to 87 - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 - - Maximum air flow 82 m³/h - - - - - - - - -
Vento Expert A100-1 S10 W V.2 BLK
(Speed II)
100-240 - 160 - yes - 0.046 - - 50/60 1100 - - - - - - IP24 - - - - 4.00 - - - - - - - 30 15 - -20...+40 42 - - - - - - - - - - 0.96 - - - - - 8 4 - - - - - - - 27 18 G3 (Option: F7 PM2,5 > 99 %*) up to 87 - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 - - Maximum air flow 82 m³/h - - - - - - - - -
Vento Expert A100-1 S10 W V.2 BLK
(Speed III)
100-240 - 160 - yes - 0.071 - - 50/60 1920 - - - - - - IP24 - - - - 6.60 - - - - - - - 58 29 - -20...+40 42 - - - - - - - - - - 0.82 - - - - - 16 8 - - - - - - - 40 30 G3 (Option: F7 PM2,5 > 99 %*) up to 87 - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 - - Maximum air flow 82 m³/h - - - - - - - - -
Vento Expert A100-1 S10 W V.2 BLK
(MAX)
100-240 - 160 - yes - 0.151 - - 50/60 2940 - - - - - - IP24 - - - - 18.00 - - - - - - - 108 54 - -20...+40 42 - - - - - - - - - - 1.20 - - - - - 30 15 - - - - - - - 51 42 G3 (Option: F7 PM2,5 > 99 %*) up to 87 - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 - - Maximum air flow 82 m³/h - - - - - - - - -
VENTO Expert A50-1 Pro (1 speed) 100-230 wall mounting 160 - - - 0.025 - - 50/60 800 - - - - 3.61 A IP24 - - - - - - 20 11 - - - - 15 8 - - 42 ≤ 93 - - - - - - - - - 1.73 - - - - - 4 2 - - - - - - - - - G3 (option: pollen filter) - - - - - - - - Filter replacement indication, Timer, Humidity sensor, External sensor connection - - - - - - - - -20...+40 - - - - -
VENTO Expert A50-1 Pro (2 speed) 100-230 wall mounting 160 - - - 0.03 - - 50/60 1300 - - - - 4.15 A IP24 - - - - - - 27 18 - - - - 30 15 - - 42 ≤ 93 - - - - - - - - - 1 - - - - - 8 4 - - - - - - - - - G3 (option: pollen filter) - - - - - - - - Filter replacement indication, Timer, Humidity sensor, External sensor connection - - - - - - - - -20...+40 - - - - -
VENTO Expert A50-1 Pro (3 speed) 100-230 wall mounting 160 - - - 0.039 - - 50/60 1900 - - - - 5.20 A IP24 - - - - - - 30 21 - - - - 50 25 - - 42 ≤ 93 - - - - - - - - - 0.75 - - - - - 14 7 - - - - - - - - - G3 (option: pollen filter) - - - - - - - - Filter replacement indication, Timer, Humidity sensor, External sensor connection - - - - - - - - -20...+40 - - - - -
1 Speed 230 ceiling mounting, wall mounting - aluzinc - - - - 60 50/60 2800 - - Supply and exhaust - - A+ - 1 - counter-flow polystyrene - - - - - - - 125 - - - - - - - - 84-95 - - 58 - - - - 31 - no - - - - - 0.5 - - - - - - - - - - - - - - - - - - - - - - - - - - 23 13 - - -
2 Speed 230 ceiling mounting, wall mounting - aluzinc - - - - 90 50/60 2800 - - Supply and exhaust - - A+ - 1 - counter-flow polystyrene - - - - - - - 125 - - - - - - - - 84-95 - - 58 - - - - 31 - no - - - - - 0.5 - - - - - - - - - - - - - - - - - - - - - - - - - - 34 26 - - -
3 Speed 230 ceiling mounting, wall mounting - aluzinc - - - - 160 50/60 2800 - - Supply and exhaust - - A+ - 1 - counter-flow polystyrene - - - - - - - 125 - - - - - - - - 84-95 - - 58 - - - - 31 - no - - - - - 0.5 - - - - - - - - - - - - - - - - - - - - - - - - - - 42 33 - - -
Vento Ergo A50 S10 Pro1
(1 speed)
- - 150 - - - 0.024 - 21 50/60 610 I - - - 4.5 - IP24 1 - - - - - - - - - - - - - - -20...+40 40 - - - - - 100-230 - - - 6 1.54 - - - - - - - - - - - - - - 22 13 G3 (Option: F8 PM2,5 > 99 %*) up to 88 - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - - - - - - - -
Vento Ergo A50 S10 Pro1
(2 speed)
- - 150 - - - 0.026 - 32 50/60 800 II - - - 5 - IP24 1 - - - - - - - - - - - - - - -20 … +40 40 - - - - - 100-230 - - - 9 1.12 - - - - - - - - - - - - - - 29 20 G3 (Option: F8 PM2,5 > 99 %*) up to 88 - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - - - - - - - -
Vento Ergo A50 S10 Pro1
(3 speed)
- - 150 - - - 0.039 - 50 50/60 1450 III - - - 7 - IP24 1 - - - - - - - - - - - - - - -20 … +40 40 - - - - - 100-230 - - - 14 1.01 - - - - - - - - - - - - - - 32 23 G3 (Option: F8 PM2,5 > 99 %*) up to 88 - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - - - - - - - -
Freshbox E-200 ERV WiFi
Speed I
230 - - polymer-coated steel - electric preheating - - 30 50/60 2000 I - - - - A - 1 - counter-flow enthalpy membrane - - - - - - - 100 - - - -15...+40 - - - - 85 - - - 30 8 - 55 - - G4 G4 + F7 (Option: H13) - - 10 - - - - 650 4.0 - 12 - - - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - -
Freshbox E-200 ERV WiFi
Speed II
230 - - polymer-coated steel - electric preheating - - 60 50/60 2000 II - - - - A - 1 - counter-flow enthalpy membrane - - - - - - - 100 - - - -15...+40 - - - - 81 - - - 30 17 - 55 - - G4 G4 + F7 (Option: H13) - - 15 - - - - 650 4.0 - 22 - - - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - -
Freshbox E-200 ERV WiFi
Speed III
230 - - polymer-coated steel - electric preheating - - 90 50/60 2000 III - - - - A - 1 - counter-flow enthalpy membrane - - - - - - - 100 - - - -15...+40 - - - - 75 - - - 30 25 - 55 - - G4 G4 + F7 (Option: H13) - - 25 - - - - 650 4.0 - 30 - - - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - -
Freshbox E-200 ERV WiFi
Speed IV
230 - - polymer-coated steel - electric preheating - - 120 50/60 2000 IV - - - - A - 1 - counter-flow enthalpy membrane - - - - - - - 100 - - - -15...+40 - - - - 68 - - - 30 33 - 55 - - G4 G4 + F7 (Option: H13) - - 44 - - - - 650 4.0 - 36 - - - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - -
Freshbox E-200 ERV WiFi
Speed V
230 - - polymer-coated steel - electric preheating - - 200 50/60 2000 V - - - - A - 1 - counter-flow enthalpy membrane - - - - - - - 100 - - - -15...+40 - - - - 66 - - - 30 56 - 55 - - G4 G4 + F7 (Option: H13) - - 134 - - - - 650 4.0 - 45 - - - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - - - - - - - -
Vento Expert A50-1 S8 W V.3 (I скорость) 100-240 - 160 - - - - - - 50/60 800 I - - - - - - - - - - - - - - - - - - 15 8 - -30...+40 41/47** - - - - - - - - - - 2.40 - - - - - 4 2 - - - - - - - 13 4 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 5.0 65.0 0.035 0.295 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 S3*** - Maximum air flow 40 m³/h with open and closed front panel manual setting of 100% speed in a mobile application - - - - - - -
Vento Expert A50-1 S8 W V.3 (II скорость) 100-240 - 160 - - - - - - 50/60 1300 II - - - - - - - - - - - - - - - - - - 30 15 - -30...+40 41/47** - - - - - - - - - - 1.44 - - - - - 8 4 - - - - - - - 25 16 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 6.0 66.0 0.040 0.300 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 S3*** - Maximum air flow 40 m³/h with open and closed front panel manual setting of 100% speed in a mobile application - - - - - - -
Vento Expert A50-1 S8 W V.3 (III скорость) 100-240 - 160 - - - - - - 50/60 1900 III - - - - - - - - - - - - - - - - - - 50 25 - -30...+40 41/47** - - - - - - - - - - 1.22 - - - - - 14 7 - - - - - - - 37 28 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 8.5 68.5 0.059 0.319 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection - D1 S3*** - Maximum air flow 40 m³/h with open and closed front panel manual setting of 100% speed in a mobile application - - - - - - -
Vento Eco2 A50-4 S Pro (1 speed) - - 160 - - - 0.033 - - 50/60 915 I - - - 2.37 - IP24 - - - - - - - - - - - - 15 - - -20(-30**) … +40 41 - - - - - 100-240 - - - - 0.57 - - - - - 4 - - - - - - - - 21 12 G3 (Option: F8 PM2,5 > 99 %*) up to 92 - - - - 15 4 Sensor Filter replacement indication, Timer - D1 S3*** - Maximum air flow 40 m³/h With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed - - - - - - -
Vento Eco2 A50-4 S Pro (2 speed) - - 160 - - - 0.047 - - 50/60 1555 II - - - 3.80 - IP24 - - - - - - - - - - - - 30 - - -20(-30**) … +40 41 - - - - - 100-240 - - - - 0.46 - - - - - 8 - - - - - - - - 27 18 G3 (Option: F8 PM2,5 > 99 %*) up to 92 - - - - 30 8 Sensor Filter replacement indication, Timer - D1 S3*** - Maximum air flow 40 m³/h With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed - - - - - - -
Vento Eco2 A50-4 S Pro (3 speed) - - 160 - - - 0.080 - - 50/60 2330 III - - - 7.61 - IP24 - - - - - - - - - - - - 50 - - -20(-30**) … +40 41 - - - - - 100-240 - - - - 0.55 - - - - - 14 - - - - - - - - 29 20 G3 (Option: F8 PM2,5 > 99 %*) up to 92 - - - - 50 14 Sensor Filter replacement indication, Timer - D1 S3*** - Maximum air flow 40 m³/h With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed - - - - - - -
Freshpoint 200-E Pro L07 230 wall mounting - - yes electric heating - up to 16 - 50/60 - - - - - - A IPX4 1 - - - - 100 - 45 - - - - - - - -30...+50 - - - - up to 85 - - - - - - - - 70 - - - - - - - - - - - - - - - - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, Carbon dioxide sensor, Air quality sensor, Light sensor - - - - - - - - - - - - - -
Freshbox E1-100 WiFi
Speed I
230 - - polymer-coated steel - electric reheating - - 30 50/60 2200 I - - - - A - 1 - counter-flow polystyrene - - - - - - - 100 - - - -20...+40 - - - - 98 - - - 350 10 8 - 31 - - G4 G4 - - 20 0.4 - 1.94 - - - - 13 - - - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
Freshbox E1-100 WiFi
Speed II
230 - - polymer-coated steel - electric reheating - - 44 50/60 2200 II - - - - A - 1 - counter-flow polystyrene - - - - - - - 100 - - - -20...+40 - - - - 95 - - - 350 10 12 - 31 - - G4 G4 - - 23 0.4 - 1.94 - - - - 20 - - - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
Freshbox E1-100 WiFi
Speed III
230 - - polymer-coated steel - electric reheating - - 60 50/60 2200 III - - - - A - 1 - counter-flow polystyrene - - - - - - - 100 - - - -20...+40 - - - - 92 - - - 350 10 17 - 31 - - G4 G4 - - 29 0.4 - 1.94 - - - - 27 - - - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
Freshbox E1-100 WiFi
Speed IV
230 - - polymer-coated steel - electric reheating - - 75 50/60 2200 IV - - - - A - 1 - counter-flow polystyrene - - - - - - - 100 - - - -20...+40 - - - - 90 - - - 350 10 21 - 31 - - G4 G4 - - 37 0.4 - 1.94 - - - - 33 - - - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
Freshbox E1-100 WiFi
Speed V
230 - - polymer-coated steel - electric reheating - - 100 50/60 2200 V - - - - A - 1 - counter-flow polystyrene - - - - - - - 100 - - - -20...+40 - - - - 89 - - - 350 10 28 - 31 - - G4 G4 - - 53 0.4 - 1.94 - - - - 39 - - - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
CIVIC EC DBE 1000 S21 V.2 400 ceiling mounting - polymer-coated steel yes electric preheating - - 1000 50/60 - - - - 258 - A+ - 3 24 counter-flow polystyrene - - - - - - -25...+40 315 - - - - - - - - 83…93* 34 - 267 - - 278 - - - - - - - - - 1.85 - 12 - 3150 - - - - - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
VENTO Ergo A50-1 Pro
(1 speed)
- wall mounting 150 - - - 0.024 - 21 50/60 610 - - - - 4.5 A IP24 - - - - - - 22 13 40 ≤ 88 - - - - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - - - - - - - -
VENTO Ergo A50-1 Pro
(2 speed)
- wall mounting 150 - - - 0.026 - 32 50/60 800 - - - - 5 A IP24 - - - - - - 29 20 40 ≤ 88 - - - - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - - - - - - - -
VENTO Ergo A50-1 Pro
(3 speed)
- wall mounting 150 - - - 0.039 - 50 50/60 1450 - - - - 7 A IP24 - - - - - - 32 23 40 ≤ 88 - - - - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - - - - - - - -
CIVIC EC DBE2 500 S21 230 ceiling mounting - polymer-coated steel yes electric preheating, electric reheating - - 510 50/60 1700 - - Supply and exhaust 130 - A - 1 24 counter-flow polystyrene - - - - - - -25...+40 250 - - - - - - - 25 mm, cellular synthetic rubber 74...86* 34 - 170 1750 - 142 - - - - G4 G4, F8 (option F8 C + H11) - - - 1.7 - 18.2 - 1750 - - - - - - - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
Freshpoint 160-E Pro L1 230 wall mounting - - yes electric heating - up to 22 - 50/60 - - - - - - A IPX4 1 - - - - 100 - 42 - - - - - - - -30...+50 - - - - up to 88 - - - - - - - - 57 - - - - - - - - - - - - - - - - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, Carbon dioxide sensor, Air quality sensor, Light sensor - - - - - - - - - - - - - -
Vento Expert A30 S10 W V.2
(1 speed)
100-240 wall mounting 100 - yes - 0.027 - 10 50/60 1600 - ≤ 81 - - 1.80 - IP24 - 21 - - - - - - - - - - - 5 G3 -15…+40 42 - - - - 30 - - - - 3 1.30 - - - - - - 1 - - - - - - - - - - - - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor - D1 - - - - - - - - - - - -
Vento Expert A30 S10 W V.2
(2 speed)
100-240 wall mounting 100 - yes - 0.037 - 20 50/60 2200 - ≤ 81 - - 3 - IP24 - 28 - - - - - - - - - - - 10 G3 -15…+40 42 - - - - 37 - - - - 6 1.08 - - - - - - 3 - - - - - - - - - - - - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor - D1 - - - - - - - - - - - -
Vento Expert A30 S10 W V.2
(3 speed)
100-240 wall mounting 100 - yes - 0.051 - 30 50/60 2500 - ≤ 81 - - 4.40 - IP24 - 31 - - - - - - - - - - - 15 G3 -15…+40 42 - - - - 40 - - - - 8 1.06 - - - - - - 4 - - - - - - - - - - - - - - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor - D1 - - - - - - - - - - - -
CIVIC EC DBE2 300 S21 V.2 230 ceiling mounting - polymer-coated steel yes electric preheating, electric reheating - - 300 50/60 - - - Supply and exhaust 80 - A+ - 1 34 counter-flow polystyrene - - - - - - -25...+40 200 - - - - - - - - 83…92* 44 - 204 700 - 83 - - - - - - - - - 1.5 - 11.7 - 1050 - - - - - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
VENTO Ergo V50 Pro (1 speed) 100-230 wall mounting 150x150 - - - 0.025 - 11 50/60 808 - - - - 4.31 A IP24 - - - - - - 28 19 19 ≤ 88 - - - - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - - - - - - - -
VENTO Ergo V50 Pro (2 speed) 100-230 wall mounting 150x150 - - - 0.029 - 24 50/60 1264 - - - - 4.92 A IP24 - - - - - - 33 24 19 ≤ 88 - - - - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - - - - - - - -
VENTO Ergo V50 Pro (3 speed) 100-230 wall mounting 150x150 - - - 0.035 - 35 50/60 1629 - - - - 5.8 A IP24 - - - - - - 39 29 19 ≤ 88 - - - - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - - - - - - - -
Vento Ergo A50-1 Pro V.3
(1 speed)
- - 150 - yes - 0.024 - 20 50/60 610 I - - - 4.5 - IP24 1 - - - - - - - - - - - - 10 - -20...+40 40 - - - - - 100-240 - - - 6 1.62 - - - - - - 3 - - - - - - - 22 13 G3 (Option: G4, F8 PM2.5 > 99 %*) up to 88 - - - - - - - Filter replacement indication, Timer, Humidity sensor yes - - - Maximum air flow 40 m³/h - - - - - - - - -
Vento Ergo A50-1 Pro V.3
(2 speed)
- - 150 - yes - 0.026 - 35 50/60 800 II - - - 5 - IP24 1 - - - - - - - - - - - - 18 - -20...+40 40 - - - - - 100-240 - - - 10 1.03 - - - - - - 5 - - - - - - - 29 20 G3 (Option: G4, F8 PM2.5 > 99 %*) up to 88 - - - - - - - Filter replacement indication, Timer, Humidity sensor yes - - - Maximum air flow 40 m³/h - - - - - - - - -
Vento Ergo A50-1 Pro V.3
(3 speed)
- - 150 - yes - 0.039 - 50 50/60 1450 III - - - 7 - IP24 1 - - - - - - - - - - - - 25 - -20...+40 40 - - - - - 100-240 - - - 14 1.01 - - - - - - 7 - - - - - - - 32 23 G3 (Option: G4, F8 PM2.5 > 99 %*) up to 88 - - - - - - - Filter replacement indication, Timer, Humidity sensor yes - - - Maximum air flow 40 m³/h - - - - - - - - -
Freshbox E-100 ERV
Speed I
230 wall mounting - polymer-coated steel yes electric preheating - - 30 50/60 2200 I - - 31 - A - 1 - counter-flow enthalpy membrane - - - - - - - 100 - - - -20...+40 - - - - 90 - - - - 10 8 - - - - G4 G4, F8 (Option: F8 C, H13) - - 12 0.4 - 3.6 - 700 - - 13 - - - - - - - - LCD Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
Freshbox E-100 ERV
Speed II
230 wall mounting - polymer-coated steel yes electric preheating - - 60 50/60 2200 II - - 31 - A - 1 - counter-flow enthalpy membrane - - - - - - - 100 - - - -20...+40 - - - - 86 - - - - 10 17 - - - - G4 G4, F8 (Option: F8 C, H13) - - 21 0.4 - 3.6 - 700 - - 27 - - - - - - - - LCD Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
Freshbox E-100 ERV
Speed III
230 wall mounting - polymer-coated steel yes electric preheating - - 100 50/60 2200 III - - 31 - A - 1 - counter-flow enthalpy membrane - - - - - - - 100 - - - -20...+40 - - - - 83 - - - - 10 28 - - - - G4 G4, F8 (Option: F8 C, H13) - - 45 0.4 - 3.6 - 700 - - 39 - - - - - - - - LCD Filter replacement indication, Timer, Weekly schedule - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
CIVIC EC LB 1200 S21 V.2 230 floor mounting - polymer-coated steel yes without heating - - 1240 50/60 - - - Supply and exhaust 352 - - 1 30 counter-flow polystyrene - - - - - - -25...+40 400 - - - - - - - 40 mm mineral wool 84…96* 40 - 345 - - 344 - - - - - - - - - 2.3 - - - - - - - - - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
VENTO A50-1 S (1 speed) 220-240 wall mounting 150 - - - 0.021 - 26 50 599 - - - - 3.68 A IP24 - - - - - - 24 14 18 ≤ 90 - - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - - - - - - - - - -
VENTO A50-1 S (2 speed) 220-240 wall mounting 150 - - - 0.026 - 53 50 1155 - - - - 4.83 A IP24 - - - - - - 34 24 18 ≤ 90 - - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - - - - - - - - - -
Vento Eco A30-4 S11 Pro
(1 Speed)
100-240 wall mounting 100 - yes - 0.021 - - 50/60 1600 I - - - 1.03 - IP24 - - - - - - - - - - - - 10 5 - -20...+40 42 - - - ≤81 - - - - - - 0.74 - - - - - 3 1 - - - - - - - 30 21 - - - - - - - - Sensor Filter replacement indication, Timer, External sensor connection - D1 - - - - - - - - - - - -
Vento Eco A30-4 S11 Pro
(2 Speed)
100-240 wall mounting 100 - yes - 0.027 - - 50/60 2200 II - - - 1.96 - IP24 - - - - - - - - - - - - 20 10 - -20...+40 42 - - - ≤81 - - - - - - 0,71 - - - - - 6 3 - - - - - - - 37 28 - - - - - - - - Sensor Filter replacement indication, Timer, External sensor connection - D1 - - - - - - - - - - - -
Vento Eco A30-4 S11 Pro
(3 Speed)
100-240 wall mounting 100 - yes - 0.038 - - 50/60 2500 III - - - 3.47 - IP24 - - - - - - - - - - - - 30 15 - -20...+40 42 - - - ≤81 - - - - - - 0.83 - - - - - 8 4 - - - - - - - 40 31 - - - - - - - - Sensor Filter replacement indication, Timer, External sensor connection - D1 - - - - - - - - - - - -
CIVIC EC DB 300 S21 230 ceiling mounting - polymer-coated steel yes without heating - - 300 50/60 2150 - - Supply and exhaust 78 - A - 1 23 counter-flow polystyrene - - - - - - -25...+40 200 - - - - - - - 25 mm, cellular synthetic rubber 76...88* 33 - 125 - - 83 - - - - G4 G4, F8 (option F8 C + H11) - - - 1.3 - 1.3 - - - - - - - - - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
Freshpoint 160-E L055 230 wall mounting - - yes electric heating - up to 22 - 50/60 - - - - - - A IPX4 1 - - - - 100 - 42 - - - - - - - -30...+50 - - - - up to 88 - - - - - - - - 57 - - - - - - - - - - - - - - - - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, Light sensor - - - - - - - - - - - - - -
VENTO V50-1 S (1 speed) 220-240 wall mounting 164x164 - - - 0.021 - 26 50 599 - - - - 3.68 A IP24 - - - - - - 24 14 19 ≤ 90 - - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - - - - - - - - - -
VENTO V50-1 S (2 speed) 220-240 wall mounting 164x164 - - - 0.026 - 53 50 1155 - - - - 4.83 A IP24 - - - - - - 34 24 19 ≤ 90 - - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - - - - - - - - - -
CIVIC EC LB 500 S14 230 floor mounting - polymer-coated steel yes without heating - - 580 50/60 1280 - - Supply and exhaust 191±3% - A - 1 25 counter-flow polystyrene - - - - - - -25...+40 250 - - - - - - - 40 mm mineral wool 75...94* 35 - 230 - - 161 - - - - G4 x 2 G4 + F8 (option: F8 C + H11) - - - 1.7 - 1.7 - - - - - - - - - - - - - Sensor Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
CIVIC EC LBE 300-E S21 230 floor mounting - polymer-coated steel yes electric preheating - - 320 50/60 2150 - - Supply and exhaust 137±3% - A - 1 21 counter-flow enthalpy membrane - - - - - - -25...+40 200 - - - - - - - 40 mm mineral wool 73...89* 31 - 125 - - 89 - - - - G4 x 2 G4 + F8 (option: F8 C + H11) - - - 0.9 - 7 - 1400 - - - - - - - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - - - - - - -
Pages